Dold 0065833, EAN: 4030641658335

Dold 0065833 UG6960.04PS/800/61 DC24V 300S safety timer relay

Dold 0065833 UG6960.04PS/800/61 DC24V 300S safety timer relay

Lieske Part No. 1001911
Mfg Part No 0065833
EAN-Code 4030641658335
Manufacturer Dold
Here only 498,11 EUR
592,75 EUR incl. VAT

Further information for Dold 0065833 UG6960.04PS/800/61 DC24V 300S safety timer relay

Technical data
1- / 2-channel2
ApplicationEmergency stop, Light barrier, Safety gate, Safety mat, Two-hand
ApprovalsUL
Cat. / PL acc. to EN ISO 13849-14/e
ConnectionPluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals
SIL CL acc. to IEC/EN 620613
SIL acc. to IEC/EN 620613
Safe output contacts, redundant NO contacts4
Thermal current Ith max.8 A
Width22,5 mm
TypeUG 6960
Cross fault detectionYes
Variant
Contact equipping2 NO contacts instantaneous, 2 NO contacts delayed
Nominal voltageDC 24 V
Terminal typepluggable terminal blocks with screw terminals
Time range300 s
Approvals and MarkingsUL-listed C/US, TÜV, UKCA
VariantSafety function light curtain, without cross fault detection. Delay function adjustable. Time delay adjustable
The safety time relay UG6960.04PS/800/61 DC24V 300S from Dold is a multifunctional device for the safe control of machines and systems. It serves to protect personnel and machinery by safely enabling and interrupting a safety circuit. The function is implemented via a delay function that can be selected using a rotary switch on the device. The device is designed for use in safety-critical applications and complies with the requirements of standards EN ISO 13849-1 and IEC/EN 62061. It has a width of 22.5 mm and is suitable for mounting in standard control panels.

Applications
This relay is intended for various safety functions, including light barriers, emergency stop circuits, safety mats, protective doors, and two-hand controls. It can also be used in combustion systems in accordance with EN 50156-1. The application is in industrial environments where safe and reliable control of movements and machine operation is required. The integrated cross-connection detection recognizes wire breaks or short circuits in the input circuit to avoid false alarms.

Functions and Equipment in Detail
The device features 2 immediate-closing contacts and 2 delayed-closing contacts, which are implemented as safe, redundant contacts. The delay function can be selected from five different modes using a rotary switch: return delay, return delay retriggerable, pickup delay, on/off wiper, and a delay function with potentiometer for manual adjustment. The time delay is adjustable up to 300 seconds. The contacts are forced-guided output contacts, meaning they are mechanically linked to ensure a safe switching function.

Technology Explained Simply
The safety functions are activated via a single push-button, with an automatic on-function also possible. The control voltage is DC 24 V. The maximum thermal current rating is 8 A. The connection technology uses removable terminal blocks with screw terminals, with variants featuring spring-cage terminals also available. The terminals are designed to allow quick replacement of the device. LED indicators signal supply voltage, safety function, time delay, and fault conditions. Fault messages are indicated by blink codes at terminals K1/K2.

Compatibility and Accessories
The device is designed for use in 2-channel safety systems. It is available with various safety functions, with the current variant including the light barrier function. Cross-connection detection is activated, increasing system reliability. The terminal blocks are removable, facilitating replacement and maintenance. The devices are designed for mounting in control panels and comply with certifications UL-listed C/US, TÜV, and UKCA.

Mounting and Installation
Mounting is in standard control panels with a width of 22.5 mm. The terminal blocks are removable, allowing device replacement without fully disconnecting the wiring. The delay function is adjusted via a rotary switch, which can be protected against unauthorized changes using a tamper-proof transparent cover. The terminal blocks are designed for use with screw terminals, with spring-cage terminals available as an option.

Operational Advantages
The safety time relay offers high reliability through redundant, safe contacts and integrated fault detection. The adjustable delay functions allow flexible adaptation to various applications. LED indicators and blink codes simplify fault diagnosis. Removable terminal blocks reduce installation and maintenance time. Certifications according to UL, TÜV, and UKCA guarantee compliance with international safety standards. The devices meet Performance Level (PL) e and Category 4 according to EN ISO 13849-1, as well as Safety Integrity Level (SIL) 3 according to IEC/EN 62061.

Safety Functions and Standards
The device is designed for use in safety-critical systems and meets the requirements of standards EN ISO 13849-1 (Category 4, PL e) and IEC/EN 62061 (SIL CL 3). The light barrier safety function enables integration into optical safety systems. Cross-connection detection ensures detection of wire breaks or short circuits in the input circuit to avoid false alarms. The devices are suitable for use in combustion systems in accordance with EN 50156-1. Certifications UL-listed C/US, TÜV, and UKCA confirm compliance with international safety requirements.
This is an offer of: