| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | For initiators and encoders |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Forcibly guided output contacts max. | 2 x 2 NO contacts |
| Indicator contacts | 2 Semiconductor monitoring outputs |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 45 mm |
| Type | UH 5947 |
| Variant |
| Contact equipping | 4 NO contacts |
| Nominal voltage | DC 24 V |
| Terminal type | pluggable terminal blocks with cage clamp terminals |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
| Variant | For PNP- NPN sensors. The transistor outputs 38 and 68 are continuously on when the unit is on operation and are switched off as soon as failure is detected |
The Dold speed monitor UH5947.04PC/200/61 DC24V is a safety-relevant monitoring switch for speed and standstill monitoring in industrial drive systems. It is designed for the safe monitoring of machine movements to prevent hazards to personnel and machinery. The device is designed for use in safety applications up to Performance Level PL e and Category 4 according to EN ISO 13849-1 as well as SIL 3 according to IEC/EN 62061. It features a 2-channel design and is designed for use with PNP and NPN initiators. The semiconductor outputs 38 and 68 are permanently switched through in fault-free operation and are switched off as soon as a fault is detected. The connection technology includes removable spring-cage terminals and removable screw terminals, with the spring-cage terminals also available in a 2-wire variant. The width is 45 mm, enabling compact mounting in standard control panels.
Applications
The speed monitor is intended for monitoring drives in machines and plants where moving parts may pose a hazard. It is particularly suitable for applications requiring safe speed monitoring in automatic and setup operation. The integrated safety door monitoring reduces the need for external safety components and enables space- and cost-saving integration. The device is compatible with all market-available motor feedback systems and proximity switches, including sin/cos, TTL, and HTL encoders. Application areas include, among others, monitoring of drive units, conveyor systems, machine tools, and other moving machine parts.
Functions and Equipment in Detail
The device features a front-mounted display enabling menu-guided parameterization. Settings can be adjusted directly on the device, allowing for time-saving commissioning without a PC. Parameters are adjustable for various operating modes, including automatic operation for monitoring a speed window and standstill, and setup operation, where the standstill path is permanently enabled. The display shows setpoint and actual values in rpm or m/min, with the setpoint additionally displayed as a frequency value. Adjustment options include a start-up bypass (0 to 999 seconds), a release delay time (0 to 999 seconds), and a shutdown monitoring for external contactors at RF1 (0.5 to 999 seconds). Monitoring of a release magnet and feedback circuits is also integrated. Operating modes can be activated via an externally connectable 2-channel operating mode selector switch.
Technology Explained Simply
The speed monitor operates with forced-guided output contacts ensuring safe signal transmission. The contact configuration includes 4 normally closed contacts arranged in two separate output paths (43/44, 53/54). Outputs can be activated via a single-button with short-circuit detection or via an automatic single-function. The thermal rating is up to 5 A (Ith max.). Certifications include UL-listed C/US, TÜV, UKCA, and CCC, enabling use in various markets. Device parameters can be transferred via an RJ45 connection (FCC Western-Modular 8P8C) using a connection cable, enabling a copy function for setting up multiple devices. Change tracking of settings allows for traceable documentation of configuration.
Compatibility and Accessories
The device is suitable for use with various encoders, including sin/cos, TTL, and HTL signals. Connection options include removable spring-cage terminals and screw terminals, with spring-cage terminals also available in a 2-wire variant. The integrated safety door monitoring allows for 1- or 2-channel configuration. Device parameters can be transferred via the RJ45 connection, enabling quick and error-free commissioning of multiple devices. Settings are available in multiple languages (German, English, French, Italian, Spanish), facilitating operation in international environments.
Mounting and Installation
Mounting is in standard control panels with a width of 45 mm. The removable terminal blocks allow for quick device replacement. Connection terminals are designed for secure connections, with spring-cage terminals providing simple and reliable connections. Installation requires no special tools, as terminals can be mounted without tools. Parameterization is done via the front-mounted display, enabling commissioning without additional equipment.
Advantages in Operation
The speed monitor offers high safety through integrated safety door monitoring, reducing the need for external safety components. Extensive diagnostic functions enable quick fault detection and reduce plant downtime. Simple and time-saving commissioning without a PC, as well as the ability to transfer device parameters with a single button press, increase efficiency during installation and maintenance. The adjustable gear ratio between two sensors enables detection of shaft breaks. Multilingual operation and comfortable, menu-guided parameterization facilitate use in various operating environments.