Further information for Dold 0065668 UG9256.11/001/61 3AC200-480V 1-10S motor starter soft start 9A
Technical data
1- / 3-phase
3
Approvals
UL
Auxiliary voltage
DC 24 V
Load current up to
9 A
Load voltage up to
3AC 200 - 480 V
On/Off Input Control
DC
Width
22,5 mm
Type
UG 9256
Signalling output
Temperature monitoring
Variant
Contact equipping
1 changeover contact
Nominal current
9 A
Nominal voltage
3AC 200 - 480 V
Ramp time
1 - 10 s
Approvals and Markings
UL-listed C/US, UKCA
Variant
With softstart. With mains isolating relay, on when no failure. Motor protection
The intelligent motor starter UG 9256 of the MINISTART series by Dold is a compact device for controlling and protecting 3-phase asynchronous motors. It combines the functions of soft start, soft stop, direction reversal, motor protection, and alarm output in one module. The width of 22.5 mm allows space-saving installation in enclosures, with the starter featuring galvanic isolation between control and main current circuits. Control is via digital inputs with DC 24 V, where relay switching for direction reversal is done without current, increasing contact life. The load voltage is 3AC 200–480 V, the rated current is 9 A, and the ramp time is adjustable from 1–10 seconds.
Applications
This motor starter is suitable for industrial applications, particularly for drives in door and gate actuators, bridge cranes, lifting and conveying systems, and process controls with stall protection. It enables reversing of 3-phase motors with powers of 30 W to 150 W, 90 W to 750 W, or 550 W to 4 kW at 400 V AC. The integrated current monitoring detects overloads if the set current is exceeded for more than 2 seconds, and shuts off the motor.
Functions and Equipment in Detail
The device features a 2-phase soft start, where motor phases are controlled via thyristors to ensure a smooth start without jerking. The soft stop extends the natural braking time to avoid abrupt stopping. Settings for start and stop moment, ramp time, and overcurrent limit are adjusted via potentiometers on absolute scales, enabling simple and time-saving commissioning. A reset button on the front panel is used for error acknowledgment, with an external reset interface also available.
Technology Explained Simply
The hybrid relay technology combines the robustness of mechanical relays with wear-free semiconductor technology. Direction reversal switching is done via relays switched without current, increasing service life. Control is via DC 24 V, with main voltage up to 3AC 480 V. Temperature monitoring of semiconductors ensures high device availability, and semiconductor voltage rating is up to 1500 V. Galvanic isolation is ensured by forced-contact contacts with a minimum spacing of 0.5 mm.
Compatibility and Accessories
The motor starter is specified according to IEC/EN 60947-4-2 and complies with UL-listed C/US and UKCA certifications. The contact configuration includes a changeover contact, used for monitoring operational readiness. An alarm output is integrated, which is active when no fault is present. Optionally, an additional alarm output can be provided according to customer requirements.
Mounting and Installation
Mounting is done in standard control panels with a width of 22.5 mm. The connection terminals are designed for connecting main and control lines. Commissioning is done via adjustment controls on the front panel, with settings directly readable from the potentiometers. Status indication is provided by four LEDs, visually signaling the operating state.
Operational Advantages
The motor starter offers high operational safety through integrated motor protection, stall protection, and temperature monitoring. The current-free relay switching reduces wear, and galvanic isolation increases safety. The compact design reduces space requirements by up to 80 % compared to conventional solutions. Simple operation and commissioning via potentiometers on absolute scales reduce installation time and error susceptibility.