The voltage and frequency monitor RP9811.03 from Dold is an industrial monitoring device for energy feed-in into the public grid. It serves to protect self-generation installations such as photovoltaic, wind power, hydro power, or combined heat and power plants against grid disturbances. The device continuously monitors the voltage and frequency of the supply network and safely disconnects the installation from the grid in case of unacceptable values, preventing damage to the installation or the public grid. It is designed for use in 3/N networks with a nominal voltage of 400/230 V and features an auxiliary voltage of AC/DC 80–230 V. The design is implemented as an installation distributor with a width of 70 mm, corresponding to the 4TE standard format.

Applications
This device is designed for grid monitoring during feed-in into low-voltage and medium-voltage networks. It is used in installations feeding into the public power grid, particularly in photovoltaic systems, wind power plants, hydro power plants, and combined heat and power plants. The default settings comply with international standards such as DIN VDE 0126-1-1:2013-08, VDE-AR-N 4105:2011-08, BDEW-Richtlinie:2008-06, CEI 0-21:2012-06, ÖVE/ÖNORM E8001-4-712:2009, and G59/3, making it usable in multiple countries. The application is particularly relevant for installations operated according to EEG 2012 and SysStabV.

Functions and Equipment in Detail
The RP9811.03 features a 2-channel design ensuring fault-tolerant monitoring. Settings are adjusted via two latching rotary switches: the first selects a pre-set standard according to country-specific requirements, while the second sets the grid type. For individual requirements, parameters can be adjusted via a menu system. The device continuously measures all required parameters and responds to deviations from predefined limits. Disconnection occurs when voltage or frequency values are unacceptable. Additionally, it provides islanding detection to safely disconnect the installation in case of grid loss.

Technology Explained Simply
Monitoring is performed via two independent channels, enabling redundant measurement. Measurement accuracy is high, and the limit values are automatically adjusted when the nominal grid voltage changes. The RoCoF (Rate of Change of Frequency, df/dt) function is parameterizable to detect rapid frequency changes. A fast disconnection can be configured in case of vector jumps. Re-energization or reconnection occurs after a configurable delay tOn. An additional fault alarm relay signals disturbances. Diagnosis is performed via a multi-colored, illuminated LCD display and LED indicators. Password protection and a tamper-proof transparent cover prevent unauthorized manipulation.

Compatibility and Accessories
The device is suitable for integration into round control and system concepts, as permission inputs are available. The coupling switches are monitored via the feedback circuit, with reaction time being measured. The terminal connections are provided for auxiliary voltage (A1, A2), measurement circuit (L1, L2, L3, N), feedback circuits (KA, K1, K2), and permission inputs (BA, B1, B2, B3). The output contacts consist of three normally open contacts (K1, K2, K3), with K3 serving as the fault alarm relay.

Mounting and Installation
The device is mounted in an installation distributor and is designed for a mounting height of 4TE (70 mm width). Installation takes place in an enclosure or distribution box. The terminal connections are clearly labeled, and functions are detailed in the data sheet. Settings are adjusted via rotary switches and menu, with default settings matching common standards.

Advantages in Operation
The RP9811.03 provides reliable protection for the installation and the public grid. Simple operation via rotary switches and menu navigation reduces setup time. Diagnosis via display and LEDs enables quick fault detection. Parameterizable functions such as RoCoF, vector jump response, and configurable reconnection delay increase flexibility. The tamper-proof cover and password protection prevent unauthorized changes to settings. Storage of disconnection time and fault memory support maintenance and documentation.