| Technical data |
| Approvals | UL |
| Enclosure design | Distribution board |
| Output contacts | 1 C/O contact |
| Time function(s) | On-delay |
| Width | 17,5 mm |
| Type | RK 7814 |
| Variant |
| Contact equipping | 1 changeover contact delayed |
| Nominal voltage | AC 230 V + AC/DC 24 V |
| Time range | 0,05 - 120 s |
| Approvals and Markings | UL-listed C/US |
The Dold time relay RK7814.81/61 is a delayed-on response control device in compact installation distributor design, designed for implementing time-dependent switching operations in industrial plants as well as in building automation. The device has a width of 17.5 mm and is designed for use in distributor boxes. It is supplied with dual voltage versions: AC 110–127 V at terminals A1–A2 and AC/DC 24 V at terminals A3–A2, enabling flexible use in different mains voltage environments. The rated voltage corresponds to the data sheet specifications and is designed for safe and reliable relay operation.
Applications
This time relay is suitable for applications requiring delayed switching functions, for example, delaying the start-up of motors, controlling lighting systems with time-based sequences, or securing processes where a defined waiting time must be observed. Its use in building automation enables, for example, the control of ventilation systems, heating systems, or roller shutter drives with programmable time delays. The robust design and UL-listed C/US certification also make it suitable for use in North America.
Functions and Equipment in Detail
The device features a changeover contact operating with delayed-on response. The delay time is continuously adjustable in the range of 0.05 to 120 seconds. The time function is externally programmed via terminals Z3, Z4, and Z5, allowing selection of four different time ranges. Adjustment is made on a relative scale in a 1:10 ratio, enabling precise adaptation to the specific application. The reset time is less than 100 ms, and the repeatability is ≤ 0.5 % of the set time range end value plus 10 ms, ensuring high reproducibility of switching operations.
Technology Explained Simply
The delayed-on function means that the contact only switches after the set time has elapsed, once the input voltage is applied. This allows electrical loads to be activated not immediately, but after a defined delay. The LED indicator signals the closed state of the output relay (contact 15–18), facilitating status monitoring during operation. Voltage influence is ≤ 1 %, and temperature influence is 0.25 % per Kelvin, ensuring stability of the time function under varying environmental conditions.
Compatibility and Accessories
The time relay is part of Dold’s RK series, which offers a comprehensive range of time functions, including delayed-on, wipe, and blink relays. The width of 17.5 mm allows mounting in standard distributor boxes. The voltage version AC 110–127 V + AC/DC 24 V is specifically designed for applications in regions with corresponding mains voltage. Certification according to IEC/EN 61812-1 ensures compliance with international safety and functional standards.
Mounting and Installation
The device is mounted in installation distributor boxes. The connection terminals are clearly labeled: A1–A2 for auxiliary voltage AC 110–127 V and A3–A2 for AC/DC 24 V. The time function is programmed via terminals Z3, Z4, and Z5, where the bridge between these terminals determines the respective time range configuration. Mounting is carried out in the usual manner for distributor devices, with electrical connections to be made according to the wiring diagrams in the data sheet.
Operational Advantages
The combination of compact design, high accuracy of the time function, and dual voltage version provides a flexible and reliable solution for time-controlled switching operations. The LED indicator enables quick status checking, and the short reset time ensures rapid response after switching off. Compliance with standard IEC/EN 61812-1 and UL certification guarantee safety and reliability in industrial use.