| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 3/e |
| Classification | For initiators |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 4 A |
| Width | 45 mm |
| Type | BH 5932 |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact |
| Nominal voltage | AC/DC 24 V |
| Response value | 8 - 14000 IPM |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | With sensor detection. PNP-input. Adjustable setting value channel 1 and 2 separated adjustable |
The Dold speed monitor BH5932.22/112/61 ACDC24V 8-14000IPM is a safety-relevant monitoring switch for continuous monitoring of rotational and linear movements in machines and plants. It is designed to prevent hazards caused by moving machine parts and is specifically conceived for use in safety-critical applications. The device features a 2-channel design and is intended for use with inductive proximity switches, with inputs configured for pnp signals. The response values are separately adjustable for channel 1 and channel 2, enabling flexible adaptation to different drive conditions.
Applications
The BH5932 is used in industrial environments where safe speed monitoring is required, for example in machine tools, conveyor systems, or packaging machines. It monitors the speed of drives and reacts to deviations from the preset value to prevent hazards to personnel or machinery. The application is not limited to rotational movements but also includes linear movements, increasing the versatility of the device.
Functions and Equipment in Detail
The device features forced-guided output contacts, consisting of two closers and one opener, ensuring secure signal transmission. The initiator connection detection checks the correct connection of the proximity switches to avoid malfunctions caused by loose or broken wires. The inputs are designed for pnp proximity switches, with npn switches being compatible in certain variants. The response values range from 8 to 14000 IPM (impulses per minute), allowing adaptation to different speeds.
Technology Explained Simply
The BH5932 operates with a nominal voltage of AC/DC 24 V and is designed for operation in industrial control systems. The forced-guided contacts ensure that the output state is physically secured, which is crucial for safety-critical applications. The thermal current rating is up to 4 A, defining the contact load capacity. The width of 45 mm allows for compact mounting in standard control panels. The certifications UL-listed C/US, TÜV, and CCC confirm compliance with international safety standards.
Compatibility and Accessories
The device is compatible with inductive proximity switches from the NA 5001, NA 5002, NA 5005, and NA 5010 series, which serve as initiators. The connection table in the datasheet shows the correct wiring of the initiators to inputs In A and In B of the BH5932. The initiators NA 5002.01.34 and NA 5005.01.34 are only suitable for devices without initiator connection detection, which must be considered during selection. The use of pnp initiators is standard, while npn initiators are optionally available.
Mounting and Installation
Mounting is done in standard control panels with a width of 45 mm. The terminal connections support stranded wires with 2 x 1.5 mm² or 2 x 2.5 mm², with the use of ferrules and plastic sleeves according to DIN 46 228-1/-2/-3/-4 recommended. The connection terminals are designed for secure and durable connections. Installation requires correct wiring of the initiators according to the connection table in the datasheet.
Advantages in Operation
The BH5932 offers high safety integrity with category 3 and performance level e according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061. The separate adjustability of response values for both channels enables precise adaptation to the specific application. The initiator connection detection increases system reliability by ensuring that sensors are correctly connected. The forced-guided contacts guarantee mechanically secured signal transmission, which is essential for safety-critical functions.