| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | Sensorless |
| Connection | Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals |
| Forcibly guided output contacts max. | 1 NC contact, 3 NO contacts |
| Indicator contacts | 1 NO contact, 2 Semiconductor monitoring outputs |
| Measuring motor voltage max. | 690 V |
| Nominal voltage | AC, DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 45 mm |
| Type | LH 5946 |
| Variant |
| Auxiliary voltage | AC 115 V |
| Contact equipping | 3 NO contacts, 1 NC contact |
| Response value | 0,2 - 4 V |
| Terminal type | screw terminals fixed |
| Time range | 0,2 - 6 s |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
The Dold Stillstandswächter LH5946.48/61 0,2-4V UHAC115V 0,2-6S is a safety-relevant, sensorless monitoring switch for direction-independent detection of standstill in 3-phase and 1-phase electric motors. The device measures the induced voltage of the decelerating motor and detects standstill as soon as this voltage drops below 0.2 V. This eliminates the need for additional sensors such as encoders or proximity switches. The function is independent of the motor's direction of rotation and enables simple retrofitting into existing systems. The stillstand monitor is suitable for use with frequency converters and features LED indicators for motor standstill, wire break, and operating voltage to visually monitor the operating status.
Applications
The stillstand monitor is used in safety-critical applications where reliable detection of motor standstill is required, for example in material handling, packaging industry, or machines with moving parts. It is designed for industrial environments and can be integrated into safety systems certified up to SIL 3 according to IEC/EN 62061 and up to Category 4/PL e according to EN ISO 13849-1. The wire break detection in the measurement circuit increases the reliability of monitoring, as a broken measurement circuit is immediately detected.
Functions and Equipment in Detail
The device features forced-guided safety output contacts with a configuration of 3 normally closed contacts and 1 normally open contact, rated for a nominal voltage of AC 250 V. The contacts are implemented as fixed screw terminals, with removable spring-loaded terminals and removable screw terminals also available as connection technology. The auxiliary voltage is AC 115 V, and the pickup voltage is adjustable within a range of 0.2 to 4 V. The standstill time can be set between 0.2 and 6 seconds to adapt the response time to the requirements of the respective system. Two semiconductor alarm outputs and an additional normally closed contact serve for status indication and integration into higher-level controls.
Technology Explained Simply
The stillstand monitor operates without external initiators and detects standstill by measuring the induced voltage in the motor. When the motor is switched off, the induced voltage drops, and as soon as it falls below the set threshold of 0.2 to 4 V, the output relay is activated. The measurement is performed directly at the motor, with a maximum motor voltage of 690 V. The LED indicators signal the operating status, with one LED for motor standstill, one for wire break, and one for operating voltage. The device width is 45 mm, enabling compact mounting in standard control panels.
Compatibility and Accessories
The stillstand monitor is compatible with the safety mounting bracket SAFEMASTER STS to extend safety functions. Certifications include UL-listed C/US, TÜV, UKCA, and CCC, enabling use in various markets. The devices are designed for use in safety systems complying with EN ISO 13849-1 (Category 4/PL e) and IEC/EN 62061 (SIL 3). The maximum thermal current load is 5 A.
Mounting and Installation
Mounting is performed in standard control panels with a width of 45 mm. The connection terminals are fixed screw terminals, with removable variants also available. Wiring is done directly to the motor connection, with wire break detection ensuring that a broken measurement circuit is detected. Commissioning requires setting the pickup voltage and standstill time, which is done via the device interface. The LED indicators support visual verification of the operating status.
Advantages in Operation
The sensorless operation reduces the number of required components and lowers maintenance requirements. The fast response time and direction-independent detection increase system reliability. Integration into existing systems is simple, as no additional sensors are required. The certifications and safety approvals according to EN ISO 13849-1 and IEC/EN 62061 enable use in safety-critical applications. The LED indicators and alarm outputs facilitate diagnosis and integration into higher-level controls.