| Technical data |
| 1- / 2-channel | 1, 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals |
| Output contacts max. | 4 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | LG 5924 |
| Variant |
| Contact equipping | 4 NO contacts |
| Nominal voltage | DC 24 V |
| Terminal type | screw terminals fixed |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
The emergency stop module LG5924.04/61 DC24V from Dold is a safety relay for use in industrial plants, ensuring the protection of personnel and machinery by safely enabling and interrupting a safety circuit. It is designed for use in safety-critical applications and meets the requirements for safety functions up to Performance Level e and Category 4 according to EN ISO 13849-1, as well as Safety Integrity Level 3 according to IEC/EN 62061. The device has a width of 22.5 mm and is suitable for mounting in standard control panels.
Applications
This module is used in plants where safe shutdown is required in hazardous situations, for example in manufacturing industry, machines with moving parts, or combustion systems, as it complies with the requirements of EN 50156-1. It serves as a central component in safety circuits triggered by emergency stop switches, sensors, or other safety functions. The 1- or 2-channel wiring allows flexible integration into existing safety architectures.
Functions and Equipment in Detail
The device features 4 normally closed contacts as output contacts, intended for controlling loads in the safety circuit. The maximum thermal current rating is 5 A, enabling use with a wide range of loads. The connection technology includes fixed screw terminals, with removable screw and spring-cage terminals available as an option. Wire connections can be made with 2 x 1.5 mm² stranded wire with ferrule and plastic sleeve, or 2 x 2.5 mm² solid wire, in accordance with DIN 46 228-1/-2/-3/-4. LED indicators for Channel 1, Channel 2, and operating status enable visual monitoring of the device status. A short-circuit detection between terminal Y1 and ground provides additional safety.
Technology Explained Simply
The safety relay operates at a nominal voltage of DC 24 V and is designed for use in industrial environments. Certifications including UL-listed C/US, TÜV, UKCA, and CCC confirm compliance with international safety standards. The safety functions are certified according to EN ISO 13849-1 and IEC/EN 62061, ensuring reliability and fault detection capability. While galvanic isolation in the circuit (for AC 230 V variants) is not specified for this DC variant, the general design of the module takes into account requirements for electrical isolation in safety systems.
Compatibility and Accessories
The module is designed for use with emergency stop switches, safety switches, and other safety functions. It can be operated in 1- or 2-channel configuration, with the 2-channel wiring enabling redundant safety functions. Optional plug-in terminal blocks are available, allowing for quick device replacement. Compatibility with standard control panels and compliance with safety function standards ensure easy integration into existing systems.
Mounting and Installation
Mounting is done in standard control panels with a width of 22.5 mm. The connection terminals are designed for use with stranded and solid conductors, with exact cross-sections specified in the datasheet. The terminals are fixed, with removable variants available as an option. Installation is carried out according to the technical specifications in the datasheet, with correct wiring of safety circuits being crucial.
Advantages in Operation
Visual indicators for operating status and channels facilitate diagnosis and maintenance. Short-circuit detection increases system safety by identifying potential faults early. Certifications according to international standards ensure use in various markets. Flexible wiring in 1- or 2-channel technology allows adaptation to different safety requirements. Robust construction and compliance with safety standards ensure reliable operation in industrial environments.