Technical data
Load current up to45 A
Load voltage up toAC 480 V
Number of poles1-pole
On/Off Input ControlDC
Width45 mm
TypePH 9270/003
Signalling outputYes
Variant
Analogue outputDC 0 - 10 V
Auxiliary voltageDC 24 V
Load currentAC 25 A
Load voltageAC 24 - 240 V
Semiconductor output1-pole
VariantNullspannungsschaltend. Mit Analogausgang. Mit Kühlkörper
The semiconductor relay PH9270.91/003/02 from Dold is an AC semiconductor relay/contactors with integrated load current measurement, designed for use in industrial applications, particularly in heating processes, where continuous monitoring of load current is required. The device features a single-pole semiconductor output and is designed as a zero-voltage switch, activating at each zero crossing of the sinusoidal supply voltage and deactivating at the next zero crossing of the load current after removal of the control voltage. This switching method ensures excellent EMC properties and minimizes disturbances in the network. Control is via a digital input interface with DC voltage, with the auxiliary voltage also being DC 24 V. The load voltage ranges from AC 24 to 240 V, with the device rated for a maximum nominal voltage up to AC 480 V. The load current is AC 25 A, with a maximum load current capacity up to 45 A (AC-51). Measurement is performed as true RMS value, enabling precise detection of alternating current.

Applications
This semiconductor relay is particularly suitable for applications in the plastics and rubber industry, for example in injection molding machines, as well as in thermoforming and packaging machines. It is also used in the food industry, where reliable and disturbance-free control of heating processes is required. The integrated load current measurement enables early fault detection, increasing productivity and reducing downtime.

Functions and Features in Detail
A central feature is the integrated analog output with a voltage of DC 0 to 10 V, providing a signal proportional to the load current. This signal can be directly evaluated by a PLC or an analog input display module, simplifying integration into existing control systems. The LED indicator at the control input (A1/A2) indicates the operating status: yellow illumination means the relay is activated, while off indicates it is not activated. The device is equipped with a heatsink that can be snapped onto a DIN rail, ensuring optimal heat dissipation and making the device ready for direct mounting.

Technology Explained Simply
The device is based on two antiparallel-connected thyristors responsible for the switching function. The DCB technology (Direct-Copper-Bonding process) ensures efficient heat dissipation, increasing service life and reliability. The zero-voltage switching minimizes electrical disturbances and ensures noiseless switching, which is advantageous in sensitive production environments. Load current measurement occurs continuously as soon as the operating voltage is applied and is converted into an analog output signal.

Compatibility and Accessories
The semiconductor relay is compliant with IEC/EN 60947-4-3 and can be used in systems with frequencies between 47 and 63 Hz. An optional overtemperature protection is available, implemented by installing a temperature-limiting switch (normally open) in the designated pocket at the bottom of the device. A suitable switch is, for example, type UP62 – 100 from UCHIYA, which opens at a heatsink temperature of 100 °C, thus providing thermal protection.

Mounting and Installation
Mounting is on a DIN rail, with the integrated heatsink enabling direct fixation. The width is 45 mm, allowing compact placement in enclosures. Terminal markings include A1+/A2 for the control input, A3+/A2 for the operating voltage and load current measurement, Out for the analog output, L1 for the mains connection, and T1 for the load output.

Operational Advantages
The device is wear-free and noiseless, resulting in high service life and low maintenance. The integrated load current measurement and analog output enable easy integration into higher-level control systems. The zero-voltage switching ensures high EMC compatibility, and the optimal heat dissipation via the heatsink guarantees reliable operation even under high loads. The maximum load current capacity of 45 A and nominal voltage up to AC 480 V make the device suitable for a wide range of industrial applications.