Technical data
1- / 3-phase1, 3
Auxiliary voltageWithout
Enclosure designDistribution board
Nominal voltage max.3/N AC 500 / 290 V
Output contacts2 C/O contacts
Width17,5 mm
TypeIL 9171
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3/N AC 400 / 230 V
Response value0,55 - 1,05 Un
Time delay1 - 20 min
Approvals and MarkingsCCC
VariantWith N. NC circuit operation. Settable time delay t1. Settable response value
The Dold undervoltage relay IL9171.12/030 is an industrial device for monitoring three-phase power networks for undervoltage. It is used for network monitoring and enables switching to a safety power supply or safety lighting in accordance with DIN VDE 0100-710 or DIN VDE 0108. The device is designed for use in 3-phase networks with neutral conductor connection, although a single-phase connection option is also provided. The nominal voltage is 3/N AC 400/230 V, with a maximum nominal voltage reaching up to 3/N AC 500/290 V. The operating voltage is drawn directly from the monitored network, as the device operates without auxiliary voltage.

Applications
This relay is used in installations where reliable power supply for safety functions is required, such as in lighting systems, emergency power supplies, or industrial controls. It is particularly suitable for applications where an automatic switch to a backup supply must occur in the event of undervoltage or phase loss. The variant with time delay t1 is designed for unstable networks, where a defined waiting period must be observed after a fault before disconnecting loads, to prevent damage to consumers such as compressors or machining equipment.

Functions and Equipment in Detail
The device operates on the standby current principle, meaning the output relay is not activated in the event of a fault. The contact configuration includes 2 changeover contacts, which can be used for controlling loads or signals. The LED indicator shows the status of the output relay – a yellow LED lights up when the contact is activated. The pickup values are adjustable in the range of 0.55 to 1.05 times nominal voltage, allowing flexible adaptation to different network conditions. The time delay t1 is also adjustable and ranges from 1 to 20 minutes. This delay ensures that the device initially indicates a normal state upon power-up, even if a fault is present, and only switches to the fault state after the delay period has elapsed.

Technology Explained Simply
Measurement is performed via the arithmetic mean of phase voltages against the neutral conductor. For variants without neutral conductor connection, L1 and L3 are measured against L2 (IK/SK 9171) or L1 and L2 against L3 (IL/SL 9171). In single-phase operation, terminals L1, L2, and L3 must be connected together. The hysteresis is approximately 4 %, meaning the reset value is below the pickup value to avoid unnecessary switching. The frequency range covers 45 to 65 Hz, sufficient for most industrial and public networks. The overload capacity is 1.15 times nominal voltage continuously.

Compatibility and Accessories
The device is designed for installation in installation distributors according to DIN 43 880. The IL 9171 form factor has a width of 17.5 mm and a depth of 59 mm, with connection terminals located at the bottom. It is compatible with 3-phase networks with and without neutral conductor connection. The IL 9171.12/030 device variant is specifically designed for applications with adjustable pickup values and time delay t1.

Mounting and Installation
Mounting is performed in standard installation distributors, with terminals located at the bottom. The mounting height is 59 mm. The devices are designed for use in enclosures and distributors complying with DIN 43 880. The connection terminals are intended for direct connection to cables, with no additional mounting aids required. Installation is performed without auxiliary voltage, as the device is powered directly from the monitored network.

Operational Advantages
The device provides reliable network monitoring without requiring additional power supply. The adjustable pickup values and time delays allow flexible adaptation to different requirements. The LED indicator simplifies diagnosis of the operating state. The standby current principle ensures that output contacts are not unintentionally activated in the event of a fault, enhancing safety. Compliance with the standard IEC/EN 60255-1 ensures the reliability and quality of the device. The IL 9171 form factor with 17.5 mm width enables compact mounting in distributors with limited space availability.