Dold 0064452, EAN: 4030641644529

Dold 0064452 MK7853N AC220-240V 30S 100MS time relay

Industrial Material > Industrial relays and contactors > Industrial Timers

Dold 0064452 MK7853N AC220-240V 30S 100MS time relay

Lieske Part No. 1565379
Mfg Part No 0064452
EAN-Code 4030641644529
Manufacturer Dold
Here only 137,81 EUR
163,99 EUR incl. VAT

Further information for Dold 0064452 MK7853N AC220-240V 30S 100MS time relay

Technical data
Enclosure designSwitch cabinet
Output contacts1 C/O contact, 1 NO contact
Time function(s)Star-Delta-Timer
Time range0,5 s - 100 s
Width22,5 mm
TypeMK 7853N
Variant
Contact changeover time100 ms
Contact equipping1 contact fleeting on make, 1 NO contact on delay
Nominal voltageAC 220 - 240 V
Time range max. value30 s
The Dold MK7853N AC220-240V 30S 100MS is a static star-delta time relay for use in industrial enclosures. It is designed for controlling three-phase motors using the star-delta starting method, to limit starting current and reduce load on the power supply and protective circuit breakers. The device features two separate output relays, activated sequentially: Relay 1 energizes upon application of operating voltage and de-energizes after the set start time has elapsed. Relay 2 energizes after a fixed contact transfer time of 100 ms and remains active as long as the relay is energized. The timing function is designed for operation at a nominal voltage of AC 220–240 V, with time ranges continuously adjustable between 0.5 s and 100 s. The maximum time range for this variant is 30 s.

Applications
This time relay is specifically designed for applications in industrial machinery, manufacturing technology, and systems with three-phase motors, where a smooth motor start is required. It is commonly used in pump systems, fan controls, or conveyor systems to minimize mechanical and electrical stress during startup. The star-delta relay function reduces starting current to approximately one-third of the rated current, preventing tripping of overcurrent protection devices.

Functions and Equipment in Detail
The device features contact configuration with one make-before-break contact and one delayed-closing contact. The output contacts include one normally open (NO) contact and one changeover (NO/NC) contact, intended for controlling contactors in star and delta operation. The contact transfer time is 100 ms, ensuring precise and reliable switching between the two operating modes. Repeatability is less than ±0.5 %, ensuring high consistency of the timing function even during repeated operation. The terminal connections are rated for conductor cross-sections up to 2.5 mm² solid or 1.5 mm² stranded, with connections possible via screw terminals or spring clamp terminals. Optional plug-in terminal blocks are available, enabling quick device replacement.

Technology Explained Simply
The MK7853N operates on the principle of static time control, where time delay is achieved through electronic circuits. The time is set continuously on an absolute scale, allowing precise adaptation to specific applications. The operating voltage is supplied via terminals A1 and A2, with a nominal voltage of AC 220–240 V. The operating voltage must be within 0.8 to 1.1 times the nominal voltage to ensure correct function. The frequency is 50/60 Hz, with tolerances of ±5 % allowed. The reset time is 40 ms, indicating the time it takes for a contact to return to its rest position after voltage is switched off.

Compatibility and Accessories
The relay is designed for use in enclosures and complies with standard IEC/DIN EN 61812-1. It is designed for continuous operation and can be operated at temperatures from -20 °C to +60 °C. The switching capacity is 3 A at AC 230 V for the closing contact and 1 A for the opening contact, according to switching group AC 15 per IEC/EN 60947-5-1. The electrical life is 500,000 switching cycles at 3 A and AC 230 V, with a mechanical life of 20 million switching cycles. The maximum permissible switching frequency is 6000 switching cycles per hour. Short-circuit resistance is ensured by a maximum fuse rating of 6 A gG/gL. The enclosure design is intended for use in enclosures, with a width of 22.5 mm. The protection rating is IP 40 for the enclosure and IP 20 for the terminals, providing protection against touch and dust, but not against water spray. The enclosure is made of thermoplastic with V0 flammability rating per UL Subj. 94, indicating a high fire protection class.

Mounting and Installation
The relay is mounted in an enclosure, with the width of 22.5 mm defining the mounting width. The terminal connections allow connection with stranded or solid conductors according to DIN 46228. Terminal markings are standardized: A1/A2 for power supply, 17/18 for star contactor, and 27/28 for delta contactor. The terminals are equipped with a yellow LED that lights up when the relay is energized, visually indicating the operating status.

Advantages in Operation
The star-delta function reduces motor starting current, minimizing load on the power supply and protective circuit breakers. High repeatability and continuous time control enable precise adaptation to different drive requirements. The robust construction and long service life ensure reliable performance even in demanding industrial environments. The integrated LED indicator simplifies diagnosis and maintenance, as the operating status is directly visible. The mounting width of 22.5 mm allows compact installation in standard enclosures.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1565379
qrcode für Dold 0064452 MK7853N AC220-240V 30S 100MS time relay