| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 3/e |
| Classification | For initiators |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 4 A |
| Width | 45 mm |
| Type | BH 5932 |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact |
| Nominal voltage | AC/DC 24 V |
| Response value | 10 - 20000 IPM |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | With sensor detection. PNP-input. Adjustable setting value channel 1 and 2 together adjustable with fine tuning to synchronise both channels |
The Dold speed monitor BH5932.22/113/61 ACDC24V10-20000IPM is a safety-relevant monitoring switch for continuous monitoring of rotational and linear movements in machines and plants. It prevents hazards caused by moving machine parts and protects personnel and machinery from damage due to unauthorized or uncontrolled movements. The device is specifically designed for use with initiators, i.e. proximity switches, and enables safe, dual-channel speed monitoring.
Applications
This speed monitor is used in industrial applications where safe motion monitoring is required, for example in manufacturing, presses, conveyor belts, or machines with rotating parts. It is suitable for detecting standstill or unauthorized rotational movements and responding accordingly, such as by switching off drives. The device is applied in environments with high safety requirements, such as in automation technology or on machines with hazard potential.
Functions and equipment in detail
The device features a dual-channel design, with both channels being adjustable together. The setpoint range is from 10 to 20000 IPM (impulses per minute), allowing flexible adaptation to different speeds. The inputs are designed for pnp proximity switches, although npn switches can also be optionally used. A special feature is the initiator connection detection, which ensures that the connected proximity switches are correctly connected. The switching simultaneity of the channels can be optimized via fine adjustment to ensure precise and synchronized response.
Technology explained simply
The speed monitor operates at a nominal voltage of AC/DC 24 V and is designed for use in industrial control systems. The output contacts are mechanically interlocked, meaning they are mechanically connected to ensure a safe switching function. The contact configuration includes 2 NO contacts and 1 NC contact, with a maximum thermal current Ith of 4 A. The width is 45 mm, enabling compact mounting in standard control panels. The feedback circuits X1–X2 allow monitoring of external contacts to integrate additional safety functions.
Compatibility and accessories
The device is compatible with various Dold proximity switches of the NA 5001, NA 5002, NA 5005, and NA 5010 series. Connection options are detailed in the data sheets and include various combinations of pnp and npn outputs. Connections are made via terminal connections, using stranded wires with 2 x 1.5 mm² or 2 x 2.5 mm² with ferrules and plastic sleeves according to DIN 46 228-1/-2/-3/-4. The terminal clamps are designed for connection to the corresponding initiator types, with exact assignments specified in the manufacturer’s connection tables.
Mounting and installation
Mounting is done in standard control panels with a width of 45 mm. The terminal clamps are designed for use with stranded wires according to DIN 46 228, with maximum cross-sections of 1.5 mm² or 2.5 mm². Wiring is carried out according to the connection tables included in the manufacturer’s data sheet.
Advantages in operation
The speed monitor provides high safety performance with Category 3 and Performance Level PL e according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061. The mechanically interlocked contacts and initiator connection detection increase system reliability. The adjustable switching simultaneity of the channels allows precise tuning, and the feedback circuits extend functionality by integrating external contacts. Certifications UL-listed C/US, TÜV, and CCC confirm compliance with international safety standards.
Approvals and safety standards
The device meets safety requirements according to EN ISO 13849-1 (Category 3, PL e) and IEC/EN 62061 (SIL 3). Approvals UL-listed C/US, TÜV, and CCC confirm suitability for use in various markets. Classification as a device for initiators emphasizes its specific use in safety-critical applications.
Application safety
The safety features of the device, such as initiator connection detection and mechanically interlocked contacts, ensure high reliability. The adjustable switching simultaneity of the channels allows precise tuning, and the feedback circuits extend functionality by integrating external contacts. Certifications UL-listed C/US, TÜV, and CCC confirm compliance with international safety standards.
Compatibility with initiators
The device is specifically designed for use with Dold proximity switches of types NA 5001, NA 5002, NA 5005, and NA 5010. Connection options are detailed in the data sheets and include various combinations of pnp and npn outputs. The terminal clamps are designed for connection to the corresponding initiator types, with exact assignments specified in the manufacturer’s connection tables.
Safety approvals
The device meets safety requirements according to EN ISO 13849-1 (Category 3, PL e) and IEC/EN 62061 (SIL 3). Approvals UL-listed C/US, TÜV, and CCC confirm suitability for use in various markets. Classification as a device for initiators emphasizes its specific use in safety-critical applications.