| Technical data |
| 1- / 2-channel | 1, 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals |
| Output contacts max. | 1 NC contact, 5 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | LG 5929 |
| Variant |
| Contact equipping | 4 NO contacts, 2 NC contacts for feedback and signal circuit |
| Nominal voltage | AC/DC 24 V |
| Terminal type | fixed terminal blocks with screw terminals |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | For 2-channel connections |
The Dold expansion module LG5929.54/100/61 AC/DC24V is a safety relay designed specifically for the safe and reliable multiplication and amplification of contacts in safety systems. It is used in conjunction with safety modules when more safety circuits are required than a single module can provide. The device features forced-guided contacts and is suitable for 1- or 2-channel wiring. The rated voltage is AC/DC 24 V, enabling flexible use in various industrial control environments. The width of 22.5 mm allows for compact mounting in standard control panels.
Applications
This expansion module is intended for use in safety-critical systems, particularly in automation technology, machine control, and combustion systems. It meets the requirements of EN 50156-1, legitimizing its use in combustion systems. The certifications UL-listed C/US, TÜV, and CCC confirm compliance with international safety standards. The maximum safety performance is Category 4 and Performance Level e according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061, highlighting its suitability for high-safety applications.
Functions and Equipment in Detail
The module provides contact configuration with 4 NO contacts and 2 NC contacts, where one NC contact is specifically designated for the feedback circuit and another for the alarm circuit. The maximum number of output contacts is 5 NO or 4 NO with 1 NC. The contacts are forced-guided, meaning that in the event of a fault in the contact drive, a safe state is automatically initiated. The operating status indicator enables visual monitoring of the operating state. The module can also be actuated using safety-oriented semiconductor outputs, such as those from BWS or emergency stop switches.
Technology Explained Simply
The technology of the expansion module is based on a relay principle, where input signals activate the relay coil to switch the contacts. The forced-guided contacts ensure that in the event of a mechanical defect, a safe state (e.g., contact opening) is automatically initiated. The maximum thermal current rating is 5 A, which is sufficient for contact loading in most industrial applications. The connection technology includes fixed screw terminals, as well as optional removable spring and screw terminals, allowing for flexible installation and maintenance. The conductor connections can be made with stranded wires up to 2 x 1.5 mm² with ferrules and plastic sleeves, or with solid conductors up to 2 x 2.5 mm².
Compatibility and Accessories
The module is designed for use in 1- and 2-channel safety systems and can be combined with suitable switching devices and controls. It is specifically designed for use with safety modules to increase the number of available safety contacts. The connection terminals are designed to support both fixed and removable variants, enabling quick replacement of the device during maintenance.
Mounting and Installation
Mounting is performed in standard control panels with a width of 22.5 mm. The terminals are designed for connection with stranded and solid conductors, with maximum cross-sections of 1.5 mm² (stranded) and 2.5 mm² (solid). The connection terminals are fixed, but removable variants are optionally available, facilitating module replacement. Installation must follow the manufacturer’s technical instructions, ensuring correct wiring of safety circuits and feedback circuits.
Operational Advantages
The expansion module provides safe and reliable contact multiplication, increasing the number of available safety contacts without compromising safety integrity. The forced-guided contacts and feedback circuit monitoring enhance fault tolerance and system safety. The operating status indicator enables quick diagnosis of faults. Compatibility with safety-oriented semiconductor outputs expands its application possibilities in modern control systems. The robust construction and international standard certifications ensure reliable performance in demanding industrial environments.