Technical data
1- / 3-phase3
ApprovalsUL
Auxiliary voltageDC 24 V
Load current up to9 A
Load voltage up to3AC 200 - 480 V
On/Off Input ControlDC
Width22,5 mm
TypeUG 9256
Signalling outputYes
Temperature monitoringYes
Variant
Contact equipping1 changeover contact
Nominal current9 A
Nominal voltage3AC 200 - 480 V
Ramp time1 - 10 s
Approvals and MarkingsUL-listed C/US, UKCA
VariantWith softstart. With mains isolating relay, on when no failure. Overcurrent protection
The intelligent motor starter UG 9256 of the MINISTART series by Dold is a compact device for controlling and protecting 3-phase asynchronous motors. It enables soft start, direction change, and protection against overcurrent as well as blocking. The device is designed for nominal voltages of 3AC 200 to 480 V and can handle load currents up to 9 A. The ramp time for soft start is adjustable between 1 and 10 seconds. The width is 22.5 mm, enabling compact mounting in enclosures. The auxiliary voltage is DC 24 V, and control is digital via DC signals. The device is designed according to IEC/EN 60947-4-2 and carries the approvals UL-listed C/US and UKCA.

Applications

The motor starter is suitable for industrial applications requiring gentle and controlled motor control. These include, for example, door and gate controls, bridge drives, lifting mechanisms, conveyor systems, and positioning drives in process engineering. The integrated blocking monitoring protects the motor against mechanical overloads caused by blockages or mechanical obstructions. The application is for motors with powers of 30 W to 150 W, 90 W to 750 W, or 550 W to 4 kW at an operating voltage of AC 400 V.

Functions and Equipment in Detail

The device offers up to six functions in one module: left rotation, right rotation, soft start, soft stop, current monitoring, and motor protection. Direction change is achieved via relay switching, with relays switched without current to ensure long service life. The soft start is implemented using thyristors, where two motor phases are phase-controlled to enable a smooth increase in current and torque. The soft stop function extends the natural coast-down time to avoid jerky stopping. Settings for start and stop torque and time are adjusted via potentiometers on absolute scales. A relay status output signals operational readiness, and an additional status output can be provided upon customer request.

Technology Explained Simply

The motor starter combines the advantages of relay technology with wear-free semiconductor technology in a hybrid relay. Galvanic isolation between control and main current circuit is achieved via forced contacts with a contact gap of at least 0.5 mm. Temperature monitoring of the semiconductors ensures high device availability, and the voltage rating of the semiconductors is up to 1500 V. Current monitoring detects overcurrent if the set current value is exceeded for more than 2 seconds. Upon reaching the trip value, the motor is switched off, and the device enters fault state 8. The fault message can be acknowledged via a reset button on the device front or via an external reset input.

Compatibility and Accessories

The device is designed for 3-phase motors and can be operated with galvanically isolated 24 V inputs for right and left rotation. The connection option for an external reset button enables flexible integration into existing control systems. The contact configuration includes a changeover contact. The approvals UL-listed C/US and UKCA ensure suitability for various markets.

Mounting and Installation

Mounting is done in standard control panels or enclosures. The width of 22.5 mm allows space-saving installation. Settings are adjusted via potentiometers on absolute scales, enabling simple and time-saving commissioning. The 4 LEDs serve as status indicators for operating states and fault messages. Connection points are clearly marked, and operation is performed via the front of the device.

Advantages in Operation

The motor starter offers high operational safety through integrated protection functions such as overcurrent protection, blocking protection, and temperature monitoring. Galvanic isolation and currentless relay switching increase service life. The combination of relay and semiconductor technology ensures reliable and low-maintenance operation. The compact design reduces space requirements by up to 80% compared to conventional solutions. Simple operation and commissioning via potentiometers on absolute scales reduce installation effort.