| Technical data |
| 2-channel safety outputs OSSD | 2 |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Width | 22,5 mm |
| Type | UG 6912.02 |
| Variant |
| Contact equipping | 2 dual-channel outputs (OSSD) |
| Approvals and Markings | UL-listed C/US, TÜV |
| Variant | 2 dual-channel outputs (OSSD) |
The Dold UG6912.02 is an output module for safe, dual-channel signal outputs in the modular safety system SAFEMASTER PRO. It is used for the safe control of external devices, such as emergency stop functions, drive disconnections, or other safety-related actuators in industrial plants. The module is specifically designed for use in safety-critical applications and provides two
safe, dual-channel outputs OSSD (Output Signal Switching Device), designed for transmitting safety-related signals.
Applications
This module is used in industrial machine and plant construction where high safety integrity is required. It is suitable for monitoring and controlling safety devices such as emergency stop buttons, safety mats, light grids, optoelectronic sensors, mechanical switches, and speed monitoring. The application is in systems certified according to standards EN ISO 13849-1 and IEC/EN 62061, and meets the requirements for
Category 4 / PL e as well as
SIL 3. These certifications guarantee high availability and reliability in the event of failure.
Functions and Equipment in Detail
The UG6912.02 features two
safe, dual-channel OSSD outputs, each with a feedback circuit and individually configurable start conditions. These feedback circuits are used to verify the integrity of the output signals and enable precise diagnosis in case of failure. The outputs are connected to the control unit and other modules via a
tray rail bus (IN-Rail Bus), enabling a compact and wiring-minimized installation in the enclosure. Communication takes place via a 5-pin bus on the rear of the module.
Technology Explained Simply
The term
OSSD (Output Signal Switching Device) describes a safe output structure used for transmitting safety-related signals in industrial controls. The dual-channel design means that each output has two independent channels operating in parallel to ensure redundant signal transmission. This increases fault tolerance and overall system safety. The
width of 22.5 mm allows for compact mounting on standard tray rails, minimizing space requirements in the enclosure. The certifications
UL-listed C/US and
TÜV confirm compliance with international safety standards.
Compatibility and Accessories
The module is part of the SAFEMASTER PRO system and works with the control unit UG 6911 and other expansion modules. It can be connected to input modules, combined input/output modules, and diagnostic modules to implement comprehensive safety functions. Communication occurs via the
IN-Rail Bus, enabling easy system expansion. Additionally, relay output modules such as UG 6912.14 and UG 6912.28 are available for potential-free contact extension of the OSSD outputs. These are wired directly to the OSSD outputs, with total current load to be considered.
Mounting and Installation
Mounting is done on a standard tray rail (DIN rail) by snapping the module into place. Connection to other modules is made via the 5-pin tray rail bus on the rear. Module configuration is performed via a Mini-USB port on a PC using the SAFEMASTER PRO Designer software, which enables graphical, drag-and-drop-based project design. The connection blocks are coded to ensure unambiguous and error-free installation.
Operational Advantages
The module reduces wiring in the enclosure and enables flexible expansion of the safety system. The integrated diagnostic function with feedback circuits and status LEDs supports quick fault localization. Software-based configuration reduces commissioning time and minimizes error sources. The certifications for
Category 4 / PL e and
SIL 3 ensure compliance with the highest safety requirements in industrial automation.