| Technical data |
| 2-channel safety outputs OSSD | 2 |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Safety inputs | 8 |
| Test outputs for sensor monitoring | 4 |
| Width | 22,5 mm |
| Type | UG 6911.10 |
| Variant |
| Contact equipping | 8 inputs, 2 dual-channel outputs (OSSD) |
| Approvals and Markings | UL-listed C/US, TÜV |
| Variant | 8 inputs. 2 dual-channel outputs (OSSD) |
The Dold UG6911.10 8E 2 zweikanalige Ausg. is a control unit for the modular safety system SAFEMASTER PRO. It serves as a central control unit for monitoring and processing safety-relevant signals in industrial plants. The device features 8 safe inputs and 2 two-channel, safe outputs in OSSD format (Safe Output Signal Device), suitable for actuating safety functions such as emergency stop, light curtains or mechanical switches. The control unit is designed for use in safety applications up to Category 4 and Performance Level e according to EN ISO 13849-1 as well as SIL 3 according to IEC/EN 62061. The width is 22.5 mm, enabling compact mounting on a support rail.
Safety functions and equipment in detail
The control unit provides 8 safe inputs, which can be used to monitor optoelectronic sensors, emergency stop buttons, safety mats or mechanical switches. The 2 two-channel OSSD outputs enable safe actuation of loads, with each output having its own feedback circuit and individually configurable start conditions. Additionally, 4 test outputs for sensor monitoring are integrated, enabling continuous testing of connected sensors. Configuration is performed via a Mini-USB interface using the SAFEMASTER PRO Designer software, allowing complex safety logics to be created graphically without extensive wiring.
Technology explained simply
The device is based on a modular system, where the control unit communicates with expansion modules via a 5-pole support rail bus (IN-Rail Bus). This bus enables flexible system expansion by simply plugging additional modules onto the support rail. The integrated safety logic automatically performs logic checks to ensure the integrity of safety functions. The use of coded connection blocks ensures a unique and error-free cable connection, increasing installation safety. Configuration via PC software reduces wiring and shortens commissioning time.
Compatibility and accessories
The UG6911.10 is part of the SAFEMASTER PRO system and can be combined with various expansion modules, including input, output and combination modules. Communication takes place via the IN-Rail Bus. Additionally, relay output modules such as UG 6912.14 or UG 6912.28 are available, which can be used for potential-free contact extension of the OSSD outputs. These modules are wired directly to the OSSD outputs, with total current requirements to be observed. The control unit can also be operated as a stand-alone device without being connected to a larger system.
Mounting and installation
Mounting is done on a standard support rail (DIN rail) with a width of 22.5 mm. Wiring is done via plug-in connection blocks, enabling quick and secure device replacement. Configuration is performed via a Mini-USB interface with a PC, where the SAFEMASTER PRO Designer software supports graphical programming of safety functions. System expansion is achieved by plugging additional modules onto the support rail, allowing flexible adaptation to specific applications.
Operational advantages
The system reduces wiring and space requirements in the enclosure due to its modular design. Graphical configuration via software enables quick and error-free commissioning. The integrated diagnostic function with status LEDs and test outputs supports fault localization. The use of coded connection blocks minimizes installation errors. The control unit is designed for use in safety-critical applications up to the highest safety category, making it suitable for machine building, manufacturing technology and other industrial sectors.
Approvals and markings
The device is certified with UL-listed C/US and TÜV approvals, confirming compliance with applicable safety standards in the USA and Canada as well as in Europe. These approvals relate to use in safety-relevant systems and ensure the reliability and safety of the device in operation.
System integration and expansion options
The SAFEMASTER PRO system allows flexible expansion by adding up to 14 expansion modules. Communication between modules takes place via the IN-Rail Bus, enabling central control and diagnosis of the entire system. The control unit UG6911.10 can also be operated without additional modules as a standalone device, making it suitable for smaller applications. Expansion options include input and output modules as well as diagnostic modules for fieldbus connectivity.
Application areas
The device is used in industrial plants where safety-relevant functions such as emergency stop, speed monitoring, light curtains or mechanical switches must be monitored. It is suitable for machine building, manufacturing plants, packaging technology and other areas where high safety requirements exist. The modular design allows adaptation to different requirements and system sizes.
Safety level and compliance with standards
The device meets the requirements of standards EN ISO 13849-1 (Category 4, Performance Level e) and IEC/EN 62061 (SIL 3). These standards define safety requirements for electrical systems in industry. Compliance with these standards ensures that the device can be used in safety-critical applications without posing an unacceptable risk to personnel or machinery.
Configuration and diagnostics
Configuration is performed via the SAFEMASTER PRO Designer software, which connects to the PC via a Mini-USB interface. The software enables graphical programming of safety functions using drag & drop. The integrated diagnostic function supports fault localization via status LEDs and test outputs. Diagnostic modules enable fieldbus connectivity for comprehensive diagnostic functions.
Modularity and expandability
The system is modular and can be flexibly expanded. The control unit UG6911.10 can be combined with up to 14 expansion modules, including input, output and combination modules. Expansion is achieved by plugging the modules onto the support rail, enabling quick and easy system expansion. Communication between modules takes place via the IN-Rail Bus.
Application areas
The device is used in industrial plants where safety-relevant functions such as emergency stop, speed monitoring, light curtains or mechanical switches must be monitored. It is suitable for machine building, manufacturing plants, packaging technology and other areas where high safety requirements exist. The modular design allows adaptation to different requirements and system sizes.
Operational advantages
- Reduced wiring
- Compact design
- Fast commissioning
- Easy expansion
- Comprehensive diagnostic functions
- High safety integrity
- Flexibility through modular design
- Support by software tools
Application areas
The device is used in industrial plants where safety-relevant functions such as emergency stop, speed monitoring, light curtains or mechanical switches must be monitored. It is suitable for machine building, manufacturing plants, packaging technology and other areas where high safety requirements exist. The modular design allows adaptation to different requirements and system sizes.