Further information for Dold 0063336 PH9260.91/120 AC200-480V AC50A semiconductor relay UH=DC4-32V

Technical data
Load current up to125 A
Load voltage up toAC 600 V
Number of poles1-pole
On/Off Input ControlAC/DC, DC
Width45 mm
TypePH 9260
Variant
Control voltageDC 4 - 32 V
Load currentAC 50 A
Load voltageAC 200 - 480 V
Semiconductor output1-pole
VariantSwitching at voltage maximum. With heigh I2t-value. Without heat sink
The Dold semiconductor relay PH9260.91/120 AC200-480V AC50A is an AC semiconductor relay with a single-pole semiconductor output, designed for use in industrial applications. It is used for wear-free and noiseless switching of loads such as heaters, motors, valves, and lighting systems. The device operates according to the standard IEC/EN 60947-4-3 and is specifically designed for operation with a control voltage in the range DC 4–32 V. The load voltage ranges between AC 200 and 480 V, with the rated load current at AC 50 A. The maximum load voltage is AC 600 V, and the maximum load current can reach up to 125 A (AC-51). The switching function in this described variant is peak-voltage switching, meaning the load circuit is closed at the point of maximum voltage. This is particularly suitable for use with transformers, as it avoids the usual inrush current during switching on.

Applications
This relay is designed for use in machine building and automation technology, for example in injection moulding machines, packaging machines, soldering systems, or machinery in the food industry. The peak-voltage switching variant is especially suitable for applications where high inrush currents must be avoided, such as with inductive loads. The zero-voltage switching function is standardly available, but cannot be activated here, as the variant is explicitly defined as peak-voltage switching.

Functions and Equipment in Detail
The device features two antiparallel-connected thyristors responsible for the switching function. The DCB technology (Direct-Copper-Bonding process) ensures excellent heat transfer, increasing thermal load capacity. The LED status indicator signals the state of the control input. The terminals are designed as box terminals, enabling a secure and easy connection. The peak blocking voltage is 1200 V or 1600 V, and the insulation voltage is 4000 V, ensuring high electrical safety. The device is designed without a heatsink, making it compact and suitable for applications where no additional cooling is required.

Technology Explained Simply
Switching is controlled via the DC 4–32 V control voltage, which activates the semiconductor output. In the peak-voltage switching variant, the load circuit is closed at the point of maximum voltage, enabling a controlled switching-on process. The I²t values (limit load integral) reach up to 18000 A²s, highlighting the relay’s ability to handle short-term current surges. The thermal resistances are specified as 0.6 K/W (junction–housing) and 12 K/W (housing–ambient), describing the thermal performance. The maximum junction temperature is 125 °C, ensuring operational safety under load conditions.

Compatibility and Accessories
The relay is designed for use in industrial control systems and can be combined with additional components such as temperature limit switches. An optional over-temperature protection is available, where a temperature limit switch (normally open) can be inserted into a designated slot on the underside. If a predefined temperature (e.g. 100 °C) is exceeded, the switch opens and protects the device. A suitable switch is the type UP62–100 from UCHIYA. Mounting is done on a DIN rail, with a width of 45 mm.

Mounting and Installation
The device is mounted on a DIN rail, with the box terminals allowing direct connection to the wiring. Mounting requires no additional tools, as the terminals are designed for quick and secure connections. The operating temperature range is from -20 °C to +40 °C, with storage up to +80 °C possible. The housing protection rating is IP 40, and the terminals are IP 20, ensuring shock protection.

Advantages in Operation
The relay offers a wear-free switching function, ensuring high service life and low maintenance. The peak-voltage switching function reduces inrush current surges when switching inductive loads, increasing the lifespan of both the load and the relay. The LED indicator allows for quick diagnosis of the operating status. The DCB technology ensures efficient heat dissipation, increasing thermal load capacity. Compliance with the standard IEC/EN 60947-4-3 guarantees reliability and safety in industrial applications.