Dold 0063315 RK9871.72/100 3/N AC400/230V50/60HZ undervoltage relay

Dold 0063315 RK9871.72/100 3/N AC400/230V50/60HZ undervoltage relay

Lieske Part No. 1002331
Mfg Part No 0063315
EAN-Code 4030641633158
Manufacturer Dold
Here only 131,87 EUR
156,93 EUR incl. VAT

Further information for Dold 0063315 RK9871.72/100 3/N AC400/230V50/60HZ undervoltage relay

Technical data
1- / 3-phase1, 3
Auxiliary voltageWithout
Enclosure designDistribution board
Nominal voltage max.3/N AC 400 / 230 V
Output contacts1 C/O contact, 2 C/O contacts
Width17,5 mm
TypeRK 9871
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3/N AC 400 / 230 V
VariantDe-energized on trip. With test-button for simulation of undervoltage
The Dold undervoltage relay RK9871.72/100 3/N AC400/230V50/60HZ is a device for monitoring three-phase power networks for undervoltage, particularly designed for use in emergency lighting systems and buildings for large gatherings of people. It enables automatic switching to a safety power supply when the network voltage drops below a predefined threshold. The device operates on the standby current principle, whereby the output relay is not activated in the event of a fault, ensuring safe and unambiguous fault detection. The RK9871.72 variant features 2 changeover contacts as contact configuration, enabling control of multiple loads or safety functions.

Applications
This relay is designed for installations complying with standards DIN VDE 0100-718:2005-10 and DIN VDE 0108-100:2005-01, particularly in buildings with heightened safety requirements. It monitors three-phase networks (3/N AC 400/230 V) and can also be used in 1- or 2-phase connection configurations, where the corresponding terminals (L1, L2, L3) must be bridged. The application is in installation distributors, with a width of 17.5 mm enabling compact mounting in standard control panels.

Functions and Equipment in Detail
The device detects undervoltage when the arithmetic mean of the three phase voltages to neutral (N) falls below the fixed pickup value of 195.5 V. Detection occurs after a duration of more than 0.5 seconds, thereby ignoring short-term voltage dips. Upon fault detection, the relay drops out, de-energizing the output relays. Return to normal operation occurs after a fixed wait time of 1 minute, if the voltage is again stable above the threshold. During this wait time, the yellow LED blinks to visually indicate the status.

Technology Explained Simply
This reduces the number of required connections and increases reliability. The LED indicator shows the operating voltage (green LED) and contact position (yellow LED). The yellow LED blinks during the 1-minute wait time to inform the user of the reset process. The pickup delay of 0.5 seconds prevents false alarms caused by short-term voltage fluctuations. The hysteresis is approximately 5 %, ensuring stable switching behavior during voltage fluctuations near the threshold.

Compatibility and Accessories
The device is designed for operating voltages of 3/N AC 400/230 V and operates in the frequency range of 45 to 65 Hz. It is designed for continuous operation and complies with overvoltage category III according to IEC 60664-1. The switching capacity is up to 2 A at 230 V for closing contacts and 1 A for opening contacts according to AC 15. The electrical life at 1 A and AC 230 V is 100,000 switching cycles. The maximum overload capacity is 1.15 times the rated voltage continuously. The rated frequency is 50/60 Hz.

Mounting and Installation
Mounting is carried out in installation distributors. The connection terminals are clearly labeled: L1, L2, L3 for the network voltage, 11, 12, 14 for the first output relay, and 21, 22, 24 for the second output relay. In single-phase operation, L1, L2, and L3 must be bridged; in two-phase operation, L2 and L3. Mounting work must only be carried out when de-energized. Adjustment work must only be performed by qualified personnel. Devices and components must be mounted and connected in accordance with local, legal, and technical regulations (e.g. VDE, TÜV, employers’ liability insurance associations).

Operational Advantages
Thanks to the LED indicator, the operating status is always visible. The test button allows functional testing without a voltage drop, enabling verification of the relay’s functionality. The fixed time delays (0.5 s for fault reporting, 1 min for reset) ensure reliable and reproducible response. The independence from phase sequence allows flexible installation without regard to phase order. Compliance with standards IEC/EN 60255-1 as well as DIN VDE 0100-718 and DIN VDE 0108-100 ensures integration into legally required safety systems.