Dold 0063271, EAN: 4030641632717

Dold 0063271 emergency stop module BH5928.47/61 AC/DC24V

Dold 0063271 emergency stop module BH5928.47/61 AC/DC24V

Lieske Part No. 1001959
Mfg Part No 0063271
EAN-Code 4030641632717
Manufacturer Dold
Here only 507,41 EUR
603,82 EUR incl. VAT

Further information for Dold 0063271 emergency stop module BH5928.47/61 AC/DC24V

Technical data
1- / 2-channel1, 2
ApprovalsUL
Cat. / PL acc. to EN ISO 13849-14/e
ConnectionPluggable screw terminals
Output contacts max.3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 620613
SIL acc. to IEC/EN 620613
Thermal current Ith max.5 A
Width45 mm
TypeBH 5928
Cross fault detectionYes
Suited as safety gate monitorYes
Variant
Contact equipping3 NO contacts, 1 NC contact instantaneous, 1 NO contact off delay
Nominal voltageAC/DC 24 V
Time range6 - 60 s
Approvals and MarkingsUL-listed C/US, TÜV, CCC
VariantWith adjustable time delay
The Dold emergency stop module BH5928.47/61 AC/DC24V 6-60S is a safety-relevant switching component for use in industrial plants. It is designed for the safe shutdown of machines and systems in emergencies, particularly in combination with sliding safety grilles or as a safety door monitor. The device is rated for operating voltages of AC/DC 24 V and features an adjustable time delay in the range of 6 to 60 seconds, ensuring controlled reactivation of machine functions after an emergency stop event. The width is 45 mm, enabling compact installation in standard control panels.

Applications
This module is designed for use in safety-critical applications, particularly in the machine and plant construction industry. It is used to implement emergency stop functions according to Stop Category 1, ensuring immediate and safe shutdown of the machine. The function as a safety door monitor enables monitoring of sliding safety grilles, ensuring that the machine can only be operated when the protective cover is closed. The application is in environments where the safety of personnel and machines is paramount.

Functions and Equipment in Detail
The device features contact configuration with 3 normally closed contacts (NO), 1 normally open contact (NC) immediate, and 1 normally closed contact delayed reactivation. The delayed reactivation function enables controlled restart of the machine after an emergency stop, with the delay time adjustable between 6 and 60 seconds. The time delay indication is provided via an LED, as well as status indicators for power supply, channel 1/2, and the delayed reactivation timer. The short-circuit detection at the single-button input (terminals S33–S34) detects a short circuit in the control circuit, preventing dangerous malfunctions. Activation occurs either via a single-button input at S33–S34 or via an automatic single-function with bridge at S13–S14.

Technology Explained Simply
The module operates at a nominal voltage of AC/DC 24 V and is suitable for use in 1- or 2-channel circuits. The removable screw terminals allow for flexible and secure wiring. The maximum permissible thermal current load is 5 A, allowing use in systems with corresponding loads. The short-circuit detection ensures that a short circuit in the emergency stop control circuit is detected, avoiding false alarms or hazardous conditions. The status indicators via LEDs provide visual feedback on the module’s operating status, facilitating troubleshooting and maintenance.

Compatibility and Accessories
The module is compatible with various safety functions, particularly in combination with emergency stop buttons and sliding safety grilles. It can be used in 1- or 2-channel circuits, with the 2-channel configuration enabling a higher safety level. The connection terminals are designed for wires with 2 x 1.5 mm² (with ferrule and plastic sleeve DIN 46 228-1/-2/-3/-4) or 2 x 2.5 mm² (with ferrule DIN 46 228-1/-2/-3). The use of removable terminal blocks simplifies installation and maintenance.

Installation and Mounting
Mounting is carried out in standard control panels with a width of 45 mm. The connection terminals are designed for use with wires according to DIN 46 228. Wiring is done via the designated connection points, taking into account the short-circuit detection at the single-button input (S33–S34) and the option for automatic single-function (S13–S14). The status indicators via LEDs allow for quick verification of the operating status during installation.

Operational Advantages
The module offers high safety integrity, confirmed by certifications UL-listed C/US, TÜV, and CCC. It complies with Performance Level (PL) e and Category 4 according to EN ISO 13849-1, as well as SIL CL 3 according to IEC/EN 62061. The integrated short-circuit detection and status indicators increase reliability and simplify maintenance. The adjustable time delay allows application-specific adaptation, enabling controlled reactivation of machine functions after an emergency stop. The compact design and removable terminals support efficient installation and maintenance in industrial environments.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1001959
qrcode für Dold 0063271 emergency stop module BH5928.47/61 AC/DC24V