Dold 0063222, EAN: 4030641632229

Dold 0063222 current relay AC0,5-5A AC/DC24-80V

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0063222 current relay AC0,5-5A AC/DC24-80V

Lieske Part No. 1320394
Mfg Part No 0063222
EAN-Code 4030641632229
Manufacturer Dold
Here only 291,36 EUR
346,72 EUR incl. VAT

Further information for Dold 0063222 current relay AC0,5-5A AC/DC24-80V

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Output contacts2 C/O contacts
Width22,5 mm
TypeMK 9053N
Operate delayYes
Variant
Auxiliary voltageAC/DC 24 - 80 V
Contact equipping2 changeover contacts
Measuring rangeAC 0,5 - 5 A
Start up delay0,1 - 20 s
Switching delay0 - 20 s
Terminal typescrew terminal fixed
Approvals and MarkingsCCC
VariantOvercurrent relay, energized on trip
The current relay MK9053N.12/010 from Dold is an overcurrent relay for monitoring single-phase DC and AC power networks. It operates on the operating current principle and is designed for use in enclosures. Device settings are adjusted via rotary switches on the front panel, ensuring simple and user-friendly configuration. The relay enables early detection of current overloads and thus supports preventive maintenance of electrical systems, helping to avoid failures and increase operational safety.

Applications

The relay is suitable for monitoring current consumption of electrical loads in industrial and railway applications. It can be used in both DC and AC systems, with measurement based on the arithmetic mean of the rectified measured current. The devices are calibrated for sinusoidal AC currents in RMS value. The measurement frequency extends up to 5 kHz, enabling use in systems with higher frequencies.

Functions and Features in Detail

The device includes an inrush current bypass, which activates once upon application of auxiliary voltage and suppresses switching events that could be triggered by high inrush current, such as from a motor. The switching delay can be set between 0 and 20 seconds, delaying switching after exceeding a threshold. The response delay is also integrated to allow delayed reaction to overloads. The setting of the pickup and drop-out values is done via rotary switches on the front of the device, with hysteresis depending on the set value.

Technology Explained Simply

The relay measures current via an internal measuring resistor (shunt) and responds when the current exceeds the set threshold. The auxiliary voltage is supplied via terminals A1 and A2 and ranges from AC/DC 24 to 80 V. Measurement is performed via terminals i and k. The output contacts consist of two changeover contacts, which are galvanically separated from the measuring circuit. The width is 22.5 mm, enabling installation in standard enclosures. The LED indicator shows operational readiness (green LED) and contact position (yellow LED).

Compatibility and Accessories

The relay is designed for use in single-phase systems and can be used as both an overcurrent and undercurrent relay. It is equipped with fixed screw terminals. Optional accessories include plug-in terminal blocks and remote potentiometers for setting the pickup value, although the latter are not galvanically separated from the measuring circuit and must be connected earth-free and potential-free. The devices comply with standards IEC/EN 60255-1 and IEC/EN 60947-1.

Mounting and Installation

Mounting is done in enclosures. The terminals are clearly labeled: A1 and A2 for auxiliary voltage, i and k for current measurement input, and contacts 11, 12, 14 and 21, 22, 24 for the two changeover contacts. The terminal type is a fixed screw terminal. The maximum permissible continuous current load is 0.5 A, and the maximum current load for 3 seconds is 8 A. When installing multiple devices in series, a 5 mm air gap is required.

Operational Advantages

Precise and reliable current monitoring enables quick fault localization and contributes to higher productivity. The integrated inrush current bypass and switching delay prevent unnecessary shutdowns due to short-term current peaks. The LED indicator provides a quick visual overview of the operating status. Galvanic separation between auxiliary and measuring circuits increases operational safety. Compliance with standards IEC/EN 60255-1 and IEC/EN 60947-1 ensures reliability and compatibility in industrial applications.
This is an offer of: