2 NO contacts instantaneous, 1 NO contact off delay
Nominal voltage
DC 24 V
Terminal type
screw terminal fixed
Time range
0,3 - 3 s
Approvals and Markings
UL-listed C/US, TÜV, CCC
Variant
2 NO instantaneous contacts and 1 release delay contact. With redundant time circuits to disconnect K1t and K2t, adjustable time.
The Dold LG5928.41/61 DC24V 0,3-3S is an emergency stop module with integrated time delay, designed for use in safety-critical systems in industrial automation. It serves the protection of personnel and machinery by implementing emergency stop circuits, particularly in combination with sliding safety grilles. The device is designed as an SNOT module (safety emergency stop technology) and enables implementation of Stop Category 1 according to applicable safety standards. The width of 22.5 mm allows for compact mounting in standard 35-mm control panels.
Applications
This module is specifically intended for use in industrial machines and systems where safe shutdown is required in hazardous situations. It is frequently used in conjunction with safety doors, sliding safety grilles, or other mechanical protective devices to ensure monitoring of sliding safety grilles. The function as a safety door monitor is explicitly provided, enabling the device to act as part of an integrated safety function in safety-relevant systems.
Functions and Equipment in Detail
The device features a contact configuration with two immediate closing contacts (instantaneous contacts) and one delayed-closing contact. The time delay during shutdown can be adjusted between 0.3 and 3 seconds, allowing for controlled shutdown of drives or other components. The adjustable time delay ensures safe shutdown of the two time relays K1t and K2t, guaranteeing controlled shutdown of the system. Control is achieved via a single-button switch connected to terminals S33–S34, or via an automatic start function activated by a bridge between S13 and S34.
Technology Explained Simply
The cross-connection detection in the emergency stop control circuit is optional and can be activated or deactivated via terminals. This function detects faults in the control circuit, such as short circuits or incorrect wiring, preventing dangerous malfunctions. The status indication for the delayed-closing time circuit, along with LED indicators for power supply, channel 1/2, and time delay, enables visual monitoring of the operating status. The connection technology includes fixed screw terminals, with removable spring terminals or removable screw terminals available as optional features. The wire connections support cross-sections up to 2.5 mm² solid or 1.5 mm² stranded wire with ferrule and plastic collar according to DIN 46228-1/-2/-3/-4.
Compatibility and Accessories
The module is designed for 1- or 2-channel wiring, enabling flexible integration into existing safety architectures. It is equipped with required certifications, including UL-listed C/US, TÜV, and CCC, allowing use in various markets. The safety functions comply with requirements of standards EN ISO 13849-1 (Performance Level PL e, Category 4) and IEC/EN 62061 (SIL CL 3 and SIL 3). The SIL requirement level (SIL CL) 3 and Safety Integrity Level (SIL) 3 ensure high reliability in the event of failure. The maximum thermal current rating is 8 A, sufficient for most industrial applications.
Mounting and Installation
Mounting is performed in standard control panels with 35-mm mounting height. The terminals are designed for secure and durable connections. The connection terminals are designed to maintain stable connections even under high mechanical stress. Connection options are clearly labeled to prevent incorrect wiring. The terminals support both screw and spring clamp connections, with the fixed screw terminal being the standard configuration.
Advantages in Operation
The module is characterized by short response time and high reliability. The integrated wire break detection at the single-button switch enhances safety by detecting incorrect wiring or short circuits. Visual indicators enable quick diagnosis during operation. The compact design and flexible control options (single-button switch or automatic start function) facilitate integration into existing systems. Compliance with safety standards and certifications ensure globally recognized quality and suitability for use in safety-critical systems.