Further information for Dold 0062583 under-voltage relay 3AC415/240V
Technical data
1- / 3-phase
1, 3
Auxiliary voltage
Without
Enclosure design
Distribution board
Nominal voltage max.
3/N AC 500 / 290 V
Output contacts
1 C/O contact
Width
17,5 mm
Type
IK 9171
Operate delay
Variant
Contact equipping
1 changeover contact
Nominal voltage
3/N AC 415 / 240 V
Response value
0,55 - 1,05 Un
Time delay
0,5 - 20 s
Approvals and Markings
UKCA
Variant
With N. NC circuit operation. Settable time delay t1. Settable response value
The Dold undervoltage relay IK9171.11/030 is an industrial-grade monitoring device for detecting undervoltages in three-phase AC networks. It serves for network monitoring and enables automatic switching to a safety power supply or safety lighting in accordance with DIN VDE 0100-710 or DIN VDE 0108. The device operates on the rest current principle, whereby the output relay is not activated in the event of a fault, ensuring safe and reliable signal transmission. It is designed for mounting in installation and industrial distributors according to DIN 43 880 and features a width of 17.5 mm, enabling compact integration into distributor enclosures.
Applications
This relay is designed for monitoring three-phase AC networks with a nominal voltage of 3/N AC 415/240 V. It can also be connected single-phase, in which case terminals L1, L2, and L3 must be bridged. The application is particularly suited for installations that must switch to emergency power supply during voltage dips or phase failure, such as hospitals, industrial plants, or safety lighting systems. The variant with time delay t1 is suitable for unstable networks, where a defined waiting period must be observed before switching to fault condition after an error.
Functions and Equipment in Detail
The device features an adjustable pickup value in the range of 0.55 to 1.05 times nominal voltage (Un). The time delay t1 can be set between 0.5 and 20 seconds, enabling delayed fault signaling during short-term voltage dips. Monitoring is performed by measuring the arithmetic mean of each phase against the neutral conductor (N). For variants without neutral conductor connection, L1 and L3 are measured against L2 (IK/SK 9171) or L1 and L2 against L3 (IL/SL 9171). The LED indicator signals the state of the output relay: a yellow LED lights up when contact 11-14 is closed. The contact configuration includes a changeover contact (1 C/O contact), which can be used for controlling auxiliary consumers or switching operations.
Technology Explained Simply
The relay operates without auxiliary voltage, meaning it is directly connected to the network to be monitored and requires no additional power supply. The pickup delay ensures that short-term voltage fluctuations do not trigger an unwanted activation. The hysteresis is approximately 4%, ensuring stable switching behavior during voltage fluctuations at the pickup value. The frequency range covers 45 to 65 Hz, enabling use in various networks. The maximum nominal voltage is 3/N AC 500/290 V, making the device suitable for higher voltages as well.
Compatibility and Accessories
The device is manufactured in I-form, featuring a depth of 59 mm and terminals located at the bottom. It is intended for mounting in installation distributors. The variant includes a neutral conductor connection and operates on the rest current principle. The time delay t1 and pickup value are adjustable. The devices comply with IEC/EN 60255-1 standards and carry the UKCA mark. The width of 17.5 mm enables compact mounting in standard distributor enclosures.
Mounting and Installation
Mounting is performed in installation distributors according to DIN 43 880. The terminals are located at the bottom of the device, enabling easy wiring. For single-phase applications, terminals L1, L2, and L3 must be connected together. The mounting width of 17.5 mm corresponds to the standard for modular components in distributors. The devices are designed for an operating voltage of 3/N AC 415/240 V, with a maximum voltage of 3/N AC 500/290 V.
Operational Advantages
The relay provides reliable network monitoring without requiring additional auxiliary voltage. The adjustable parameters such as pickup value and time delay allow individual adaptation to specific applications. The LED indicator provides visual status indication, which is helpful for maintenance and diagnostics. The width of 17.5 mm and I-form ensure compact and standardized mounting. Compliance with IEC/EN 60255-1 and the UKCA mark guarantee adherence to applicable safety and quality standards.