Dold 0062509, EAN: 4030641625092

Dold 0062509 semiconductor contactor AC200-480V AC40A

Dold 0062509 semiconductor contactor AC200-480V AC40A

Lieske Part No. 1001623
Mfg Part No 0062509
EAN-Code 4030641625092
Manufacturer Dold
Here only 197,10 EUR
234,55 EUR incl. VAT

Further information for Dold 0062509 semiconductor contactor AC200-480V AC40A

Technical data
Load current up to40 A
Load voltage up toAC 480 V
Number of poles1-pole
On/Off Input ControlDC
Width45 mm
TypePH 9270
Signalling outputYes
Variant
Auxiliary voltageDC 24 V
Load currentAC 40 A
Load voltageAC 200 - 480 V
Semiconductor output1-pole
VariantSwitching at zero crossing. Control via A1/A2 with under- and over current monitoring and PNP transistor output with de-energized on trip. With heat sink
The Dold PH9270.91/000/02 AC200-480V AC40A is an AC semiconductor relay / contactor designed for frequent, wear-free, and noiseless switching and monitoring of electrical loads in industrial applications. It is particularly suitable for use in machines and plants of the plastics and rubber industry, packaging industry, soldering systems, and the food industry. The device features integrated load circuit monitoring, which activates an alarm output in case of deviations from the set load current, interruption of the load circuit, defective power semiconductor, or missing load voltage. Monitoring is continuous as long as auxiliary voltage is applied.

Applications
This semiconductor relay is used for controlling and monitoring heating elements, motors, valves, and lighting systems. When controlling motors, an acceleration bypass time must be considered in the control system to prevent the overcurrent monitoring from triggering during startup. The zero-voltage switching ensures a soft switching operation, extending the lifespan of both the load and the relay. Typical applications include injection molding machines, extruders, thermoforming and blow molding machines, as well as packaging machines.

Functions and Features in Detail
The device is zero-voltage switching, meaning the load circuit is activated at the next zero crossing of the sinusoidal mains voltage as soon as control voltage is applied. After removal of the control voltage, the relay switches off at the next zero crossing of the load current. This minimizes switching disturbances and current surges. The load voltage range is AC 200 to 480 V, and the load current is up to 40 A (AC 51). Control is via the digital input A1/A2 with an auxiliary voltage of DC 24 V. A PNP semiconductor alarm output operating on the rest current principle signals fault conditions. Status indication is provided by a dual-color LED: yellow indicates the relay is activated, off means it is not activated. The Alarm LED shows green when no fault is present, red when a fault occurs (e.g., thyristor defect, load circuit interruption, current value outside the adjustment range, or mains voltage < 100 V AC), and off when no auxiliary voltage is applied.

Technology Explained Simply
The relay is based on two antiparallel-connected thyristors, which enable switching in an alternating current circuit. The DCB technology (Direct-Copper-Bonding process) ensures optimal heat dissipation, reducing thermal stress and increasing service life. The device is equipped with a heat sink that can snap onto a DIN rail, allowing direct mounting. The width is 45 mm, making it suitable for standard control panels. The integrated load circuit monitoring detects faults such as partial load faults, load circuit interruptions, over- or under-current, fuse failure, and thyristor faults. Monitoring is performed in accordance with the standard IEC/EN 60947-4-3.

Compatibility and Accessories
The semiconductor relay is designed for use in control systems with PLC-compatible alarm output (PNP). On request, an NPN variant is also available. Control is via a digital input with DC 24 V. The load connection terminals are designed for connecting mains and load lines. Optionally, a temperature limit switch (normally open) can be inserted into the designated pocket on the underside of the device to activate an overtemperature protection function. If the heat sink temperature exceeds the set limit (e.g., 100 °C), the switch opens and protects the device from thermal overload. An example of a suitable temperature limit switch is the type UP62 – 100 from UCHIYA.

Mounting and Installation
Mounting is done on a DIN rail, with the device directly snap-fitting onto the rail using the integrated heat sink. Installation must be carried out by a qualified electrician. Terminal markings are clearly defined: A1+/A2 for the control input, A3+/A2 for the operating voltage and load circuit monitoring, Alarm for the semiconductor alarm output, L1 for the mains connection, and T1 for the load output. The degree of protection is IP 20, providing protection against contact with fingers or similar objects.

Operational Advantages
The device offers wear-free and noiseless operation, reducing maintenance requirements and extending the lifespan of the load. The integrated load circuit monitoring enables rapid fault detection and localization, increasing operational availability. Zero-voltage switching reduces switching disturbances and current surges. Optimal heat dissipation via DCB technology and heat sink ensures reliable operation even under high loads. The PLC-compatible alarm output allows easy integration into existing control systems. The width of 45 mm and DIN rail mounting facilitate installation in standard control panels.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1001623
qrcode für Dold 0062509 semiconductor contactor AC200-480V AC40A