| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 3/e |
| Classification | For initiators |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 4 A |
| Width | 45 mm |
| Type | BH 5932 |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact |
| Nominal voltage | AC/DC 24 V |
| Response value | 15 IPM |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | With sensor detection. PNP-input. Fixed setting value |
The Dold speed monitor BH5932.22/110/61 AC/DC24V 15IPM is a safety-relevant monitoring switch for industrial drives. It is designed for the safe detection of rotational and linear movements in machines and systems, preventing hazards to people and machinery caused by moving parts. The device is designed for use in safety-critical applications and meets the requirements for functional safety in industrial automation.
Applications
The BH5932 is used in machine building, packaging technology, material handling, and other industries where safe speed monitoring is required. It monitors the speed of drives and safely shuts down the machine if a predefined response threshold (here 15 IPM) is undershot. The application is particularly common in systems certified according to EN ISO 13849-1 and IEC/EN 62061 to ensure the safety of work systems.
Functions and Equipment in Detail
The device features a 2-channel design and is equipped with forced-guided contacts, ensuring secure signal transmission. The contact configuration includes 2 NO contacts and 1 NC contact, with contacts rated for a maximum thermal current load of 4 A. Initiator connection detection monitors the connection to external proximity switches and ensures correct signal transmission. The input is designed for PNP proximity switches, with the variant featuring a fixed response threshold.
Technology Explained Simply
The speed monitor operates at a nominal voltage of AC/DC 24 V and is designed for use in industrial environments. The forced-guided contacts prevent the contacts from switching independently, which is required for safety-critical applications. Classification as an initiator device means it functions as an input element in a safety function system. Safety categories PL e and Category 3 according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061, guarantee high safety performance. The width is 45 mm, enabling compact mounting in standard control panels.
Compatibility and Accessories
The device is compatible with inductive proximity switches from the NA 5001, NA 5002, NA 5005, and NA 5010 series. The connection table in the datasheet shows the correct wiring of initiators to inputs In A and In B of the BH5932. According to the manufacturer, initiators NA 5002.01.34 and NA 5005.01.34 are only suitable for devices without initiator connection detection, which is not the case for this variant. The connection terminals are designed for stranded wires up to 2.5 mm² with ferrules DIN 46 228-1/-2/-3/-4.
Mounting and Installation
Mounting is done in standard control panels with a width of 45 mm. The connection terminals allow the connection of wires with a cross-section up to 2.5 mm². Wiring of the initiators must follow the manufacturer’s connection table, taking into account the color coding (brown, blue, black) and assignment to inputs In A and In B. The devices are designed for industrial environments and comply with certifications UL-listed C/US, TÜV, and CCC.
Advantages in Operation
The BH5932 offers high safety performance through the combination of forced-guided contacts, initiator connection detection, and a fixed response threshold. The 2-channel structure increases the reliability of monitoring. The compact design and standard nominal voltage of 24 V simplify integration into existing systems. Certifications according to UL, TÜV, and CCC ensure usability in various markets. The thermal current rating of 4 A is sufficient for most industrial applications.