| Technical data |
| 1- / 3-phase | 1 |
| Enclosure design | Distribution board |
| Measuring range | AC 0,175 - 1 A |
| Output contacts | 1 C/O contact |
| Width | 17,5 mm |
| Type | IK 8839 |
| Variant |
| Auxiliary voltage | AC/DC 24 V |
| Contact equipping | 1 changeover contact |
| Switching point | 1 A max. 20 A |
| Variant | With an inverted output. Gold plated contacts to switch low loads |
The
current monitor from manufacturer Dold, type IK8839.11/102, is an
industrial measuring device for functional monitoring of primarily
electro-thermal consumers, such as heating coils or pipe tracing heaters. The device checks whether operating current flows when the consumer is switched on, and reacts to deviations from the pre-set switching point. It is designed for use in
installation distributors and is mounted on a
DIN rail. The width is 17.5 mm, enabling compact integration into standard control panels.
Applications
The current monitor is specifically designed for monitoring heating units and other consumers where a constant current flow is required for proper function. It is used in industrial plants, building technology, and process control systems, where interruption of current flow can lead to functional failures or safety risks. The application is for
continuous operation at ambient temperatures from -20 °C to +60 °C.
Functions and Equipment in Detail
The device features a
fixed switching point of 1 A, located within the measuring range of 0.175 A to 1 A. When this switching point is undershot, the output is activated. The variant IK8839.11/102 is equipped with an
inverted output, meaning the relay output switches when the switching point is reached. The contact configuration includes
1 changeover contact, used for switching operations. The contacts are
gold-plated, ensuring reliable switching even under
light load conditions. The response time is approximately 60 ms.
Technology Explained Simply
The current monitor measures the flowing current via inputs i and k. When the current is below 1 A (within the measuring range of 0.175–1 A), the output is activated via the relay. The auxiliary voltage is
AC/DC 24 V, with the voltage range for AC being between 0.8 and 1.1 times the nominal voltage. The device consumes 2.2 VA apparent power at AC 230 V. The
switching capacity according to AC 15 is 3 A / AC 230 V for the make contact and 1 A / AC 230 V for the break contact. The electrical life is approximately 100,000 switching cycles at 5 A and AC 230 V. The mechanical life is 20 million switching operations. The
switching tolerance is ±15 %, and the frequency influence is at 48–52 Hz with a deviation range of -8 % to +3 %.
Compatibility and Accessories
The device is designed for use with
electro-thermal consumers. It can be combined with other devices from the IK8839 series, such as variant IK8839.11/001 with fixed response delay or IK8839.11/004 with gold contacts and delay. The terminal clamps are designed for conductor cross-sections of 2 x 2.5 mm² (solid) or 2 x 1.5 mm² (stranded wire with sleeve DIN 46228-1/-2/-3/-4). The stripping length is 10 mm, and the tightening torque for the terminals is 0.8 Nm.
Mounting and Installation
Mounting is done via a
DIN rail (IEC/EN 60715). The terminals are equipped with self-releasing flat clamps, ensuring a simple and secure connection. The terminal designations are clearly defined: A1/A2 for voltage supply, i/k for current measurement inputs, and 11/12/14 for the changeover contacts. The device indicators consist of two LEDs: the upper LED lights up when auxiliary voltage is applied, and the lower LED indicates the activated output relay.
Operational Advantages
The current monitor offers high
overload capacity with a maximum current of 20 A (continuous) and 150 A (for 2 seconds). The
protection rating of the housing is IP 40, and of the terminals IP 20. The housing is made of thermoplastic with V0 behaviour according to UL Subj. 94, ensuring good flame retardancy. The EMC characteristics comply with standards IEC/EN 61000-4-2 to -6, including immunity to electrostatic discharge (8 kV) and high-frequency radiation (10 V/m). The operating altitude is limited to below 2000 m.
Approvals and Standards
The device complies with standard
IEC/EN 60255-1 and is suitable for use in industrial plants. Terminal designation follows
EN 50005. The operating temperature ranges and climatic resistance (20 / 060 / 04 according to IEC/EN 60068-1) ensure reliable function under industrial conditions. Vibration resistance is specified with an amplitude of 0.35 mm and a frequency of 10–55 Hz according to IEC/EN 60068-2-6.
Indicators and Status Monitoring
Two integrated LEDs serve for visual status indication: the upper LED indicates operational readiness (when auxiliary voltage is applied), and the lower LED indicates the status of the output relay. These indicators facilitate diagnosis and maintenance during operation.