Dold 0062039, EAN: 4030641620394

Dold 0062039 emergency stop module AC/DC24V 60-600S

Dold 0062039 emergency stop module AC/DC24V 60-600S

Lieske Part No. 1001960
Mfg Part No 0062039
EAN-Code 4030641620394
Manufacturer Dold
Here only 507,41 EUR
603,82 EUR incl. VAT

Further information for Dold 0062039 emergency stop module AC/DC24V 60-600S

Technical data
1- / 2-channel1, 2
ApprovalsUL
Cat. / PL acc. to EN ISO 13849-14/e
ConnectionPluggable screw terminals
Output contacts max.3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 620613
SIL acc. to IEC/EN 620613
Thermal current Ith max.5 A
Width45 mm
TypeBH 5928
Cross fault detectionYes
Suited as safety gate monitorYes
Variant
Contact equipping3 NO contacts, 1 NC contact instantaneous, 1 NO contact off delay
Nominal voltageAC/DC 24 V
Time range60 - 600 s
Approvals and MarkingsUL-listed C/US, TÜV, CCC
VariantWith adjustable time delay
The Dold emergency stop module BH5928.47/61 AC/DC24V 60-600S is a safety relay for use in industrial plants, specifically designed for implementing emergency stop functions and monitoring sliding safety grilles. It protects personnel and machinery by safely disconnecting drives or moving parts in hazardous situations. The device is designed as a safety module with adjustable time delay and enables implementation of Stop Category 1 according to EN ISO 13849-1. The width is 45 mm, making it suitable for use in standard control panels.

Applications
This module is intended for use in safety-critical systems, particularly in the machine and plant construction industry. It is used for monitoring safety doors, sliding safety grilles, and other mechanical protective devices that require immediate machine shutdown upon opening or malfunction. The function as a safety door monitor is explicitly confirmed, allowing integration into systems with movable safety grilles or doors. The time delay range of 60 to 600 seconds enables controlled shutdown, which can be adjusted according to application requirements.

Functions and Equipment in Detail
The device features contact configuration with 3 NO contacts, 1 NC contact immediately, and 1 NO contact with delayed reset. The output contacts are designed to provide up to 3 immediate NO contacts and 3 delayed NO contacts. The time delay is adjustable and can be set between 60 and 600 seconds depending on requirements. The status indicator for the delayed reset timing circuit enables visual monitoring of the operating state. LED indicators for power supply, channel 1/2, and time delay support diagnostics and maintenance. Connection is made via removable screw terminals, enabling flexible and secure connections.

Technology Explained Simply
The module operates at a nominal voltage of AC/DC 24 V and is designed for operation in single- or dual-channel configurations. Cross-connection detection at the single-button input (connected to terminals S33–S34) detects incorrect wiring in the control circuit, enhancing safety. Activation occurs either via a single-button input at S33–S34 or via an automatic start function activated by a bridge at S13–S14. The thermal current rating is up to 5 A, defining the contact load capacity. Wire connection options include 2 x 1.5 mm² stranded wire with ferrule and plastic sleeve DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with ferrule DIN 46 228-1/-2/-3.

Compatibility and Accessories
The module is designed for use in safety-relevant control systems and complies with the requirements of standards EN ISO 13849-1 (Performance Level PL e, Category 4) and IEC/EN 62061 (SIL CL 3). Certifications include UL-listed C/US, TÜV, and CCC. It is designed as a safety device for industrial environments, with certifications enabling use in various regions. Compatibility with other safety components is ensured through standardized connection terminals and compliance with the mentioned standards.

Mounting and Installation
Mounting is performed in standard control panels with a width of 45 mm. Removable screw terminals facilitate installation and maintenance. Connection terminals are clearly labeled, with terminals S33–S34 designated for the single-button input and S13–S14 for the automatic start function. Wire connections are made according to specified cross-sections (1.5 mm² or 2.5 mm²) with appropriate ferrules. Adherence to connection instructions is critical for functional safety.

Operational Advantages
The module provides high safety integrity by complying with SIL 3 according to IEC/EN 62061 and PL e according to EN ISO 13849-1. The adjustable time delay allows application-specific adaptation, enabling controlled shutdown. LED indicators and the status indicator for the delayed timing circuit simplify diagnostics and maintenance. Cross-connection detection increases system reliability by identifying incorrect wiring in the control circuit. The use of removable terminals and clear labeling of connections reduces error sources during installation and maintenance.