| Technical data |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable screw terminals |
| Output contacts max. | 1 NC contact, 3 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Safety integrity level according to EN 574 | lll C |
| Safety integrity level according to EN ISO 13851 | lll C |
| Thermal current Ith max. | 5 A |
| Width | 45 mm |
| Type | BH 5933 |
| Variant |
| Contact equipping | 3 NO contacts, 1 NC contact |
| Nominal voltage | AC 110 V |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA |
The Dold BH5933.48/61 AC110V is a
two-hand safety relay of the BH 5933 series, designed for use in safety-critical applications in industrial automation. It enables the safe release and interruption of safety circuits, particularly in machines with hazardous closing movements such as metalworking presses. The device allows integration of two-hand switches, permitting operation only when both hands of the operator are actuated on the switch, thereby reducing the risk of accidents. The width is 45 mm, making it suitable for standard control panels.
Applications
This safety relay is used in systems requiring high safety standards, particularly in metalworking, where presses and other machines with hazardous movements are operated. It is designed for use in safety controls that allow operation only under specific, controlled conditions. The use of two-hand switches ensures that the operator has both hands positioned on the switch before the machine cycle starts, promoting safe working practices.
Functions and Equipment in Detail
The device features a contact configuration with
3 NO contacts and
1 NC contact, enabling flexible interconnection in safety circuits. The rated voltage is
AC 110 V, and the relay is designed for operation in industrial environments. The output contacts are rated for a maximum thermal current of
5 A, covering typical safety application loads. Connection is made via
removable screw terminals, ensuring a secure and reliable connection even under high vibration loads. The terminals are designed for wires with 2 x 1.5 mm² or 2 x 2.5 mm² with ferrules and plastic collars according to DIN 46228-1/-2/-3/-4.
Technology Explained Simply
The safety relay operates on the principle of safe signal processing. It monitors two inputs, each supplied by a two-hand switch. The output is activated only when both inputs are simultaneously activated. This prevents the machine cycle from being triggered by a single hand, increasing safety. The device includes a feedback circuit (Y1–Y2) that enables monitoring of external contactors to achieve contact multiplication or amplification. The integrated monitoring protects against overvoltage and short circuits, enhancing reliability during operation.
Compatibility and Accessories
The relay is designed for use in safety controls complying with standards EN ISO 13849-1, IEC/EN 62061, and EN 574. It is certified with
Performance Level (PL) e and
Category 4 according to EN ISO 13849-1, representing the highest safety level for safety-related control systems. Additionally, it complies with
SIL 3 according to IEC/EN 62061 and
Safety Level Type III C according to EN ISO 13851. Certifications include UL-listed C/US, TÜV, and UKCA, enabling use in various markets.
Mounting and Installation
Mounting is done in standard control panels with a width of 45 mm. The removable screw terminals facilitate installation and maintenance. The connection terminals are designed to ensure a secure connection even under high vibration loads. Installation must follow the manufacturer’s technical instructions, ensuring correct wiring of inputs and outputs. The device indicators are intended for visual monitoring of the operating status.
Advantages in Operation
The safety relay provides a compact, ready-to-connect solution for two-hand switching, reducing the need for conventional contactor controls. The integrated monitoring and high safety certification ensure reliable performance in critical applications. The use of removable screw terminals simplifies maintenance and replacement. Certifications according to UL, TÜV, and UKCA allow use in various regions without additional conformity assessments. The maximum thermal load capacity of 5 A is sufficient for most industrial safety applications.