Dold 0061918, EAN: 4030641619183

Dold 0061918 emergency stop module LG5924.48/61 230V

Dold 0061918 emergency stop module LG5924.48/61 230V

Lieske Part No. 1002011
Mfg Part No 0061918
EAN-Code 4030641619183
Manufacturer Dold
Here only 206,63 EUR
245,89 EUR incl. VAT

Further information for Dold 0061918 emergency stop module LG5924.48/61 230V

Technical data
1- / 2-channel1, 2
ApprovalsUL
Cat. / PL acc. to EN ISO 13849-14/e
ConnectionPluggable cage clamp terminals, Pluggable screw terminals, Screw terminals
Output contacts max.4 NO contacts
SIL CL acc. to IEC/EN 620613
SIL acc. to IEC/EN 620613
Thermal current Ith max.5 A
Width22,5 mm
TypeLG 5924
Variant
Contact equipping3 NO contacts, 1 NC contact
Nominal voltageAC 230 V 50/60 Hz
Terminal typescrew terminals fixed
Approvals and MarkingsUL-listed C/US, TÜV, UKCA, CCC
The emergency stop module LG 5924 from Dold is a safety-oriented switching component for use in industrial plants, particularly for protecting personnel and machinery. It is designed for the safe enabling and interruption of a safety circuit and is intended for applications requiring high reliability and fault detection. The device is available in the variant LG5924.48/61 AC50/60HZ 230V and operates at a nominal voltage of AC 230 V at 50/60 Hz. It has a width of 22.5 mm, making it suitable for standard control panels.

Applications
This module is intended for safety applications up to Performance Level (PL) e and Category 4 according to EN ISO 13849-1. It also meets the Safety Integrity Level (SIL) 3 and SIL CL 3 requirements as per IEC/EN 62061. These certifications make it suitable for critical installations, such as in manufacturing industry, combustion systems (according to EN 50156-1), or automated process plants, where immediate and reliable shutdown is required in case of failure. The 1- or 2-channel wiring enables flexible integration into existing safety architectures.

Functions and Equipment in Detail
The module features a contact configuration with 3 normally closed contacts and 1 normally open contact, where up to 4 normally closed contacts can be used as output contacts. The connection technology includes fixed screw terminals, as well as optionally removable spring-cage and screw terminals, enabling flexible installation and maintenance. The wire connections are designed for 2 x 1.5 mm² stranded wire with ferrule and plastic collar or 2 x 2.5 mm² solid wire according to DIN 46 228-1/-2/-3/-4. Galvanic isolation in the circuit ensures high electrical safety. Additionally, short-circuit detection between terminal Y1 and ground is integrated to detect faults in the connection area early.

Technology Explained Simply
The module’s function is based on the safe control of a safety circuit. In the event of an emergency stop, the circuit is interrupted, safely shutting down the machine or plant. Integrated LED indicators signal the operating status and the status of channels 1 and 2, enabling quick diagnosis during operation. The thermal current Ith is up to 5 A, defining the contact load capacity. Certifications UL-listed C/US, TÜV, UKCA, and CCC confirm compliance with international safety standards.

Compatibility and Accessories
The module is designed for use in safety control systems meeting the specified standards. It can be combined with plug-in connection blocks to enable quick device replacement — this is optionally available. Compatibility with existing safety architectures is ensured by the 1- or 2-channel wiring and galvanic isolation.

Mounting and Installation
Mounting is done in standard control panels with a width of 22.5 mm. The terminals are designed for use with stranded or solid wires according to DIN 46 228. The connection terminals are fixed, with optionally removable variants available. Installation does not require special tools, but correct contact assignment and compliance with safety regulations must be ensured.

Advantages in Operation
The integrated short-circuit detection and LED indicators increase operational safety and simplify maintenance. Certifications according to EN ISO 13849-1 and IEC/EN 62061 guarantee high reliability in safety-critical applications. The option to use the module in 1- or 2-channel configuration offers flexibility in system planning. Galvanic isolation protects against interference in the circuit and increases the device’s service life.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1002011
qrcode für Dold 0061918 emergency stop module LG5924.48/61 230V