2 NO contacts instantaneous, 1 NO contact off delay
Nominal voltage
DC 24 V
Terminal type
screw terminal fixed
Time range
1 - 10 s
Approvals and Markings
UL-listed C/US, TÜV, CCC
Variant
2 NO instantaneous contacts and 1 release delay contact. With redundant time circuits to disconnect K1t and K2t, adjustable time.
The Dold LG5928.41/61 DC24V 1-10S is an emergency stop module with integrated time delay, specifically designed for the safe control of machines and systems. It serves the protective function for personnel and machines, particularly in applications where a Stop Category 1 according to EN ISO 13849-1 must be implemented. The device is suitable as a safety door monitor and enables monitoring of sliding safety grilles. The width is 22.5 mm, allowing compact mounting in standard control panels. The rated voltage is DC 24 V, and the time delay is adjustable in the range of 1 to 10 seconds.
Applications
This module is used in industrial systems where safe shutdown in emergencies is required. It is particularly suitable for applications requiring a delayed reset time for the deactivation of time relays (K1t and K2t) to ensure that machines cannot be immediately restarted. The function as a safety door monitor enables monitoring of access protection systems, thereby increasing operator safety during machine operation.
Functions and Equipment in Detail
The device features two immediate-closing contacts and one delayed-closing contact. The time delay for the delayed contact is adjustable between 1 and 10 seconds. The connection technology includes fixed screw terminals, with removable spring terminals and removable screw terminals also available. Wire connections can be made with stranded conductors up to 2 x 1.5 mm² with ferrules and plastic collars DIN 46228-1/-2/-3/-4, or with solid conductors up to 2 x 2.5 mm² DIN 46228-1/-2/-3. Status indicators for the delayed timing circuit, as well as LED indicators for power supply, channel 1/2, and time delay, support diagnostics and monitoring during operation.
Technology Explained Simply
The time delay ensures that after triggering the emergency stop button, the machine does not shut down immediately but only after a defined delay period. This is particularly necessary in complex systems to ensure that all movements have completed before operation can resume. Cross-circuit detection at the single button (when connected to terminals S33–S34) detects faults in the control circuit, enhancing safety. Activation occurs either via the single button at S33–S34 or via an automatic activation function with a bridge at S13–S34. The function can be configured optionally with or without cross-circuit detection in the emergency stop control circuit.
Compatibility and Accessories
The module is suitable for 1- or 2-channel wiring, increasing flexibility when integrating into existing safety architectures. The terminals are designed to be compatible with various conductor cross-sections. Optional plug-in terminal blocks are available, enabling quick device replacement. Certifications include UL-listed C/US, TÜV, and CCC, allowing use in various markets.
Mounting and Installation
Mounting is performed in standard control panels with a width of 22.5 mm. The terminals are designed for secure and reliable connections. The terminals are designed for use with stranded and solid conductors according to DIN 46228-1/-2/-3/-4. Installation requires no special tools, as standard screw terminals are used. The LED indicators facilitate commissioning and troubleshooting.
Advantages in Operation
The module offers high safety integrity with Performance Level (PL) e and Category 4 according to EN ISO 13849-1, as well as Safety Integrity Level (SIL CL) 3 according to IEC/EN 62061. The SIL 3 classification according to IEC/EN 61508 and IEC/EN 61511 ensures reliability in critical applications. The short response time and clear status indication improve efficiency in troubleshooting. The choice between 1- and 2-channel wiring, along with the option for cross-circuit detection, expands application possibilities. The thermal load capacity is up to 8 A, sufficient for most industrial applications.