Technical data
Braking current adjustable up to max.
32 A
Braking time adjustable up to max.
31 s
Width
45 mm
Type
BA 9034N
Automatic standstill monitoring
Signalling output
Variant
Braking current
25 A
Braking time
2 - 11 s
Contact equipping
1 changeover contact
Nominal voltage
AC 400 V
Approvals and Markings
UKCA
Variant
With standstill detection. Adjustable braking current
The Dold motor brake device BA9034N is an electronic device for DC braking of single- and three-phase asynchronous motors. It is used in industrial applications where safe and precise braking of the motor is required, for example in sawmills, centrifuges, woodworking machines, textile machines or conveyor systems. The device is developed in accordance with the standard IEC/EN 60947-4-2 and offers a compact design with a width of 45 mm, allowing it to be mounted on a 35 mm standard DIN rail. It is designed for a nominal voltage of AC 400 V ± 10 % and a nominal frequency of 50/60 Hz ± 3 Hz.
Applications
This motor brake device is designed for use in various industrial machines and systems where rapid and reliable stopping of the motor is required. The application areas include particularly machines with rotating parts, where uncontrolled coasting motion could lead to safety risks. The integrated standstill detection ensures that braking is only activated when the motor is actually in motion, thereby increasing operational safety.
Functions and equipment in detail
The device features an integrated brake contactor function, which supplies the DC braking voltage to the stator winding of the motor via terminals T1 and T2. Braking is achieved via a single-phase rectifier, allowing DC current to flow through the stator winding and thus decelerate the motor. The braking current is adjustable and can be set within a range of 5 to 32 Aeff, with the specified variant providing a braking current of 25 A. The braking time is also adjustable and can be selected between 2 and 11 seconds, with a maximum braking time of 31 seconds possible. The braking delay time is self-optimizing and set between 0.2 and 2 seconds to dissipate residual EMF.
Technology explained simply
The BA9034N is controlled by a microcontroller that monitors and controls the braking processes. The supply voltage is connected to terminals L1 and L2, which closes the interlock contact for the motor contactor. A green LED indicates that the device is operational. When the motor contactor is switched off, the brake contactor is activated after a safety delay for the set braking time. The automatic standstill detection ensures that braking is only activated when the motor is running. The alarm outputs allow the indication of operating states and faults.
Compatibility and accessories
The device is suitable for all single- and three-phase asynchronous motors. It can be integrated into existing systems without requiring a current measuring device. The contact configuration includes a changeover contact with a switching capacity of 5 A / AC 250 V. The electrical service life is 1 x 10⁵ switching operations, and the mechanical service life is 50 x 10⁶ switching operations. The operating temperature range is between 0 °C and +45 °C, and the storage temperature range is between -25 °C and +75 °C.
Mounting and installation
The device is mounted on a 35 mm standard DIN rail, enabling easy and quick installation. The connection terminals are clearly labeled, allowing wiring without additional tools. The green LED RUN" indicates the operating status, while a red LED "Error" blinks in case of faults. The yellow LED "I B signals that braking current is flowing, with the display remaining on continuously or blinking depending on the set maximum braking time (11 s or 31 s).
Advantages in operation
The motor brake device provides higher safety through shorter coasting times and reduces maintenance costs, as it is wear-free and maintenance-free. The simple commissioning without a current measuring device and the integrated brake contactor function reduce the number of required components. Reliability is enhanced by automatic standstill detection and alarm outputs for fault conditions. Compliance with the standard IEC/EN 60947-4-2 ensures safe and standard-compliant use in industrial systems.