Further information for Dold 0061012 GF9016 3AC50/60Hz200V UHDC24V 11kW soft starter
Technical data
Extra functions
Mains monitoring, Temperature monitoring
For three-phase motors, 400 V up to
22 kW
Load voltage up to
3AC 400 V
Width
45 mm, 52,5 mm
Type
GF 9016
Signalling output
Variant
Auxiliary voltage
DC 24 V
Mains / motor voltage
3AC 200 V
Nominal motor power
11 kW
Approvals and Markings
UKCA
The soft start / soft stop device GF9016 from Dold is an electronic control unit for smooth start-up and shut-down of three-phase asynchronous motors. It reduces mechanical stress in the drive system and relieves the supplying network by lowering inrush currents. The device operates with a 2-phase motor control, where two motor phases are controlled via power semiconductors (thyristors) using phase-angle control. This allows currents and motor torque to increase gradually, ensuring a jerk-free start. After start-up, the power semiconductors are bypassed via internal relay contacts to minimize power losses in the device. The soft stop function extends the natural coast-down time to avoid abrupt stopping of the drive.
Applications
This device is suitable for drives with gear, belt, or chain drives, as well as for conveyor belts, fans, pumps, compressors, woodworking machines, centrifuges, packaging machines, and door drives. It is particularly used where sudden start-up torque must be avoided to protect mechanical components and extend the service life of drive parts.
Functions and Equipment in Detail
The device features separate adjustment options for start-up and shut-down time, as well as for start-up voltage. Optionally, a kick-start function can be activated, enabling a short, strong start-up impulse. Control is performed via terminals X2 (Start/Stop) and X3 (Kick-start). The auxiliary voltage is DC 24 V. The device is designed for a supply/motor voltage of 3AC 200 V, with the load voltage reaching up to 3AC 400 V. The motor rated power is 11 kW, with the device designed for motors up to 22 kW.
Technology Explained Simply
The phase-angle control via thyristors enables controlled voltage increase on two motor phases. This gradually builds up the motor torque, reducing mechanical stress during start-up. The third phase is connected directly, ensuring stable rotating field formation. Bypassing the power semiconductors after start-up minimizes power losses and device heating. Network monitoring and temperature monitoring ensure safe operation and protect the device against overloads.
Compatibility and Accessories
The device is compliant with IEC/EN 60947-4-2 and carries the UKCA mark. It is suitable for W3 circuit configuration, enabling flexible installation in various circuits. The width is 45 mm for motors up to 15 kW and 52.5 mm for motors up to 22 kW. An alarm output is integrated, signaling faults and bypassed status via terminals X5/X6 and X7/X8. Indication is provided by a green LED (ready for operation) and a yellow LED (fault condition, e.g. supply voltage fault, overload, electronic fault, ignition fault, or motor phase fault).
Mounting and Installation
The device is designed for installation in enclosures and can be mounted in standard control panels. Terminal labeling is clearly defined: L1, L2, L3 for supply voltage, T1, T2, T3 for motor voltage, X1 for +24 V (in wide voltage variant), X2 for Start/Stop, X3 for Kick-start, X4 for 0 V, X5/X6 for fault alarm output, and X7/X8 for bypassed status. Installation is carried out according to the manufacturer’s technical instructions.
Operational Advantages
Smooth start-up and shut-down reduce wear on motors and mechanical drive components, increasing service life. Network relief through reduced inrush currents protects the supply infrastructure. Compact installation and simple operation facilitate integration into existing systems. Integrated fault diagnosis via LED indicators enables quick identification of malfunctions.