Further information for Dold 0060264 emergency stop module BH5928.92/61 DC24V 0.5-5S
Technical data
1- / 2-channel
1, 2
Approvals
UL
Cat. / PL acc. to EN ISO 13849-1
4/e
Connection
Pluggable screw terminals
Output contacts max.
3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 62061
3
SIL acc. to IEC/EN 62061
3
Thermal current Ith max.
5 A
Width
45 mm
Type
BH 5928
Cross fault detection
Suited as safety gate monitor
Variant
Contact equipping
2 NO contacts, 1 NC contact instantaneous, 3 NO contacts off delay
Nominal voltage
DC 24 V
Time range
0,5 - 5 s
Approvals and Markings
UL-listed C/US, TÜV, CCC
Variant
With adjustable time delay
The Dold BH5928.92/61 DC24V 0,5-5S is an emergency stop module with integrated time delay, specifically designed for use in safety-critical systems. It serves the protective function for personnel and machinery, particularly in the monitoring of sliding safety grilles and in the implementation of emergency stop circuits according to Stop Category 1. The device is designed as a safety component and meets the requirements for safety integrity in industrial applications.
Applications
This module is used in systems where safe shutdown is required in hazardous situations. It is suitable as a safety door monitor to supervise access to hazardous areas. The functions enable integration into safety control systems certified according to EN ISO 13849-1 and IEC/EN 62061. Applications include machine building, manufacturing technology, and other industries where compliance with safety standards is mandatory.
Functions and Equipment in Detail
The device features contact configuration with 2 NO contacts, 1 NC contact immediately, and 3 NO contacts with delayed reset. The time delay is adjustable in the range of 0.5 to 5 seconds. The output contacts are rated for a thermal current of up to 5 A. The connection technology uses removable screw terminals, enabling flexible wiring. The conductor connections support stranded wires with 2 x 1.5 mm² with ferrule and plastic collar DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² with ferrule DIN 46 228-1/-2/-3.
Technology Explained Simply
The time delay enables controlled shutdown, for example, to safely bring machines to a standstill without immediate danger. The delayed reset contacts ensure that shutdown does not occur immediately, but after a defined delay time. The cross-circuit detection checks the integrity of the control line and detects faults such as short circuits or line breaks. The status indicator for the delayed reset time circuit, as well as LED indicators for power, channel 1/2, and time delay, support diagnosis and maintenance. Activation occurs either via a single button at terminals S33-S34 or via an automatic enable function with a bridge at S13-S14.
Compatibility and Accessories
The module is suitable for 1- or 2-channel wiring, increasing flexibility when integrating into existing safety architectures. Certifications include UL-listed C/US, TÜV, and CCC, enabling use in various markets. The safety integrity corresponds to Performance Level (PL) e and Category 4 according to EN ISO 13849-1, as well as SIL CL 3 according to IEC/EN 62061. The requirements for safety functions are thus fulfilled for critical applications.
Mounting and Installation
Mounting is done in standard control panels with a width of 45 mm. The removable terminal blocks facilitate installation and maintenance. The connection terminals are clearly labeled to avoid incorrect connections. Compliance with technical data and safety instructions is essential during mounting and commissioning.
Advantages in Operation
The combination of time delay, cross-circuit detection, and clear indicators enables a reliable and maintenance-friendly safety function. Compliance with standards EN ISO 13849-1 and IEC/EN 62061 ensures conformity with applicable safety standards. The modular design and clear structure of the connections facilitate integration into existing systems and troubleshooting in case of faults.