| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 3/e |
| Classification | For initiators |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 4 A |
| Width | 45 mm |
| Type | BH 5932 |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact |
| Nominal voltage | AC/DC 24 V |
| Response value | 8 - 14000 IPM |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | Without sensor detection. NPN-input. Adjustable setting value channel 1 and 2 together adjustable with fine tuning to synchronise both channels |
The Dold speed monitor BH5932.22/103/61 ACDC24V 5-10500IPM is a two-channel safety device for monitoring rotational and linear movements in machines and systems. It is designed for the safe detection of speeds or standstills to prevent hazards to personnel and machinery caused by moving parts. The device is specifically designed for use with initiators, such as inductive proximity switches, and provides a reliable, redundant monitoring function.
Applications
The BH5932 is used in industrial applications where safe motion monitoring is required, for example in manufacturing, packaging technology, or drives with rotating parts. It is suitable for ensuring that machines are only started when the speed has reached a specified value, or for immediately triggering a shutdown in case of unexpected standstill. The device is applied in environments requiring high safety standards, such as automation technology with integrated safety functions.
Functions and Equipment in Detail
The device features an adjustable setpoint range of 8 to 14000 IPM (impulses per minute), which is set for both channels simultaneously. The switching simultaneity of the channels can be optimized via fine adjustment to ensure precise synchronization. The inputs are designed for NPN proximity switches and support initiator connection recognition, enabling secure verification of the connection between sensor and device. The output contacts are fail-safe, consisting of two normally closed contacts and one normally open contact, enabling secure signal transmission even in the event of mechanical faults.
Technology Explained Simply
The BH5932 operates at a nominal voltage of AC/DC 24 V and is designed for use in industrial control systems. The fail-safe contacts ensure that the switching position is mechanically secured — even if one contact fails, the other switching position remains active, increasing safety. The maximum thermal current load is 4 A, allowing use with various loads. The width of 45 mm enables compact mounting in standard control panels. The device class is designed for initiators, meaning it can be directly connected to sensors such as inductive proximity switches.
Compatibility and Accessories
The device is compatible with Dold Minitiator proximity switches of types NA 5001, NA 5002, NA 5005, and NA 5010. The connection configuration depends on the initiator type and device variant; for example, with NPN inputs, connections In A / + In B and In A / - In B are used. The terminal connections support conductors up to 2.5 mm² with sleeves according to DIN 46 228-1/-2/-3/-4. The use of initiator connection recognition requires specific sensors, with types NA 5002.01.34 and NA 5005.01.34 only suitable for devices without initiator connection recognition.
Mounting and Installation
Mounting is carried out in standard control panels with a width of 45 mm. The terminal connections are designed for stranded conductors up to 2.5 mm², with the use of sleeves and plastic collars according to DIN 46 228-1/-2/-3/-4 recommended. Electrical connections are made via the designated connection points, ensuring correct wire assignment (e.g., brown for positive, blue for negative). The devices are designed for industrial environments and require no special mounting aids.
Advantages in Operation
The BH5932 offers high safety performance with Category 3 and Performance Level PL e according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061. The two-channel design with fail-safe contacts increases reliability and enables redundant monitoring. The adjustable switching simultaneity ensures precise synchronization of the channels, which is important for critical applications. Certifications UL-listed C/US, TÜV, and CCC confirm compliance with international safety standards. The devices are designed for use in environments with increased safety requirements and support integration into safety-relevant control systems.