Further information for Dold 0060057 GB9034 60A AC50/60Hz 230V motor brake relay
Technical data
Braking current adjustable up to max.
600 A
Braking time adjustable up to max.
320 s
Width
110 mm
Type
GB 9034
Automatic standstill monitoring
External brake contactor required
Signalling output
Temperature monitoring
Variant
Auxiliary voltage
Without
Braking current
60 A
Nominal voltage
AC 230 V
Approvals and Markings
UKCA
The electronic motor brake device GB 9034 of the MINISTOP series by Dold is designed for wear-free braking of three-phase and alternating current asynchronous motors. It is designed for drives that must be reliably braked for safety and functional reasons, for example in sawmills, centrifuges, woodworking machines, textile machines or conveyor systems. The device enables precise control of the braking process and reduces coast-down times, thereby increasing operational safety and economic efficiency. Braking is achieved via DC braking with single-phase rectification, where the braking current is applied to the stator winding of the motor via terminals U and V.
Applications
This motor brake device is designed for industrial applications where fast and reliable braking is required. It is particularly used in machines that reach high rotational speeds during operation and where uncontrolled continued rotation must be avoided during shutdown. The device variant with 60 A braking current is suitable for motors with corresponding power. The integrated standstill monitoring ensures that the braking process is automatically switched off as soon as the motor stops, or signals faults via an alarm output.
Functions and Equipment in Detail
The device features automatic standstill monitoring, which monitors the motor status and switches off the braking current once standstill is reached. The braking time is adjustable up to a maximum of 320 seconds, allowing the braking process to be adapted to the specific requirements of the drive. A potential-free alarm output signals if the motor has not come to a stop within the maximum braking time. Temperature monitoring protects the device and the motor from overheating. The braking current strength is adjustable up to a maximum of 600 A, with the variant specified here having a fixed braking current of 60 A.
Technology Explained Simply
DC braking is achieved via a single-phase rectifier, which converts alternating voltage into direct voltage and applies it to the stator winding of the motor. This causes the motor to be braked by electromagnetic friction. Braking is activated by an external brake contactor, which is controlled via terminals 1 and 2. The safety time between switching off the motor contactor and switching on the brake contactor prevents induced voltages from damaging the power section. The supply voltage is connected to terminals L1 and L2, with the ready LED indicating that voltage is present and the device is operational.
Compatibility and Accessories
The device is suitable for asynchronous motors and complies with the standard IEC/EN 60947-4-2. It requires an external brake contactor, which is controlled via terminals 1 and 2. The auxiliary voltage is not present in this variant. The width is 110 mm. The device variant is designed for a nominal voltage of AC 230 V. The UKCA approval is available. The device variant does not include an integrated brake contactor, as this is only standardly integrated in devices up to 60 A — here, an external brake contactor is required.
Mounting and Installation
Installation is carried out in the existing control system. The supply voltage is connected to L1 and L2, the motor to U, V and W. The external brake contactor is controlled via terminals 1 and 2. The interlock contacts (terminals 8 and 9) ensure that the motor contactor can only be switched on when the brake contactor is switched off. The connection terminals are clearly labeled to ensure error-free installation. Functions such as standstill monitoring and alarm output are accessible via the respective terminals (e.g. 13/14, 33/34).
Advantages in Operation
The motor brake device offers wear-free and maintenance-free operation, as no mechanical brakes are required. The shorter coast-down time increases safety and enables faster restart. Adjustable parameters such as braking time and braking current allow individual adaptation to the respective drive. The integrated temperature monitoring and standstill monitoring increase the reliability of the system. Simple integration into existing systems reduces installation effort and commissioning time.