Dold 0060034, EAN: 4030641600341

Dold 0060034 RP5995S AC230V expansion module

Industrial Material > Industrial relays and contactors > Electronic modules

Dold 0060034 RP5995S AC230V expansion module

Lieske Part No. 1323597
Mfg Part No 0060034
EAN-Code 4030641600341
Manufacturer Dold
Here only 369,15 EUR
439,29 EUR incl. VAT

Further information for Dold 0060034 RP5995S AC230V expansion module

Technical data
Alarm inputs8
Alarm inputs extendable up to88
Enclosure designDistribution board
Operating principleDe-energized on trip, Energized on trip
Optical signalLED
Special featuresBus-compatible, Configurable
Width70 mm
TypeRP 5995
Operate delayYes
Optional buzzerYes
Variant
Contact equipping2 x 1 NO contact
Nominal voltageAC 230 V
Terminal typescrew terminal fixed
VariantRS485 Bus not isolated
The Dold RP5995S AC230V expansion module is an industrial component for fault warning systems in the INFOMASTER B-system, specifically designed to extend the number of fault warning inputs. It is used in conjunction with the base module RP 5994 to achieve a monitoring capacity of up to 88 fault warning inputs. The device is designed for use in installation distributors and has a width of 70 mm, making it suitable for standard control panels. It operates at a nominal voltage of AC 230 V and is designed for use in industrial plants where reliable and rapid fault localization is required.

Applications

The expansion module RP5995S is used in production plants, manufacturing lines, and other industrial environments where continuous monitoring of machines and processes is necessary. It enables rapid cause and fault localization to reduce production downtime. The expandability from 8 to up to 88 fault warning inputs allows flexible adaptation to different plant sizes and complexities. It is particularly suitable for plants requiring central fault warning with optical and acoustic signaling.

Functions and equipment in detail

The module features 8 fault warning inputs, each equipped with an LED for optical signaling. The inputs can be operated in either current-on or current-off principle, with the operating mode being adjustable. The response delay of the warning inputs is also adjustable and can be varied between 0 and 10 seconds to avoid false alarms caused by short-term disturbances. The front of the module is fitted with reset buttons for horn, fault warning, and general warning, which can be used depending on the settings. Additionally, there is a connection option for a remote reset button, which can be used for horn, general warning, or fault warning depending on the configuration.

Technology explained simply

The device operates on the principle of a new/first-value or collective fault warning system, with the operating mode being configurable. The fault warning inputs can be operated in either current-on or current-off principle, meaning a signal is triggered either by interruption (current-off) or by connection (current-on). The adjustable response delay allows filtering of short-term disturbances to increase the reliability of the warning. Optical signaling is provided by LEDs directly on the device. Relay outputs for general warning and horn are optionally available, with ordering by request. The module is bus-capable and can be connected via an RS485 bus, with galvanic isolation available as an option.

Compatibility and accessories

The expansion module RP5995S is specifically developed for use with the base module RP 5994. It is part of the INFOMASTER B-system and can be combined with other components such as the warning panel EH 5994, EH 5995, or the text panel EH 5996. The accessories allow individual design of the display and integration into existing monitoring systems. The alarm generator RK 8832 can be connected as an acoustic signal device to support visual and acoustic warning.

Mounting and installation

The module is installed in an installation distributor and is designed for mounting in standard control panels. The terminal type is a fixed screw terminal, ensuring a secure and reliable connection. Wiring is carried out according to the circuit diagrams in the data sheet, with connections for fault warning inputs, relay outputs, and bus connection clearly defined. Address setting is done via a rotary switch ADR on each expansion module to enable communication in the bus system.

Advantages in operation

The system's expandability from 8 to up to 88 fault warning inputs offers high flexibility for different applications. The adjustable operating modes and response delay increase the reliability of the warning and reduce false alarms. The front-mounted reset buttons and the option for remote resetting simplify operation and enable quick response to disturbances. Integration into the INFOMASTER B-system enables central monitoring and control of the plant, thereby increasing operational safety and maintenance efficiency.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1323597
qrcode für Dold 0060034 RP5995S AC230V expansion module