Further information for Dold 0059747 GF9016/100 3AC50/60HZ 230V 11KW soft starter
Technical data
Extra functions
Mains monitoring, Temperature monitoring
For three-phase motors, 400 V up to
22 kW
Load voltage up to
3AC 400 V
Width
45 mm, 52,5 mm
Type
GF 9016
Signalling output
Variant
Auxiliary voltage
Without
Mains / motor voltage
3AC 230 V
Nominal motor power
11 kW
Approvals and Markings
UKCA
The soft starter GF 9016 from Dold is an electronic control device for smooth start-up and shut-down of three-phase asynchronous motors. It reduces mechanical stress in the drive system and enables jerk-free operation through controlled current and torque regulation. The device is designed for motors with a rated power of 11 kW and operates at a supply voltage of 3AC 230 V. The width is 45 mm, making it suitable for space-saving installation in enclosures. It complies with the standard IEC/EN 60947-4-2 and is equipped with UKCA approval.
Applications
This device is intended for drives with mechanical transmission elements such as gearboxes, belt or chain drives. Typical applications include conveyor belts, fans, pumps, compressors, woodworking machines, centrifuges, packaging machines, and door drives. The soft start function reduces mechanical stress and extends the service life of drive components. The soft stop function prevents abrupt stopping and thus minimizes recoil forces in the drive system.
Functions and Equipment in Detail
The device controls two motor phases via phase-cut control using power semiconductors (thyristors). This allows the current to be built up gradually, enabling a smooth increase in motor torque. After start-up, the power semiconductors are bypassed via internal relay contacts to minimize power losses in the device. Optionally, a kick-start function can be activated, providing a short impulse at the beginning of start-up. The W3 circuit is also possible.
Technology Explained Simply
Control is achieved via an electronic ramp control, which continuously increases the voltage on two motor phases. The third phase is connected directly, resulting in a two-phase control. The load voltage is up to 3AC 400 V, and the device is designed for motors up to 22 kW. Network monitoring and temperature monitoring ensure safe operation. In case of faults, a yellow LED blinks in a defined pattern, indicating fault codes. A green LED indicates the ready-to-operate status. The alarm outputs X5/X6 and X7/X8 enable the indication of faults and the status of the bypass.
Compatibility and Accessories
The device is designed for three-phase asynchronous motors and can be mounted in enclosures with standard width. It is operational without auxiliary voltage. The terminal designation includes supply voltage (L1, L2, L3), motor voltage (T1, T2, T3), as well as signal inputs and outputs (X1 to X8). The connection terminals are designed for integration into existing control systems.
Mounting and Installation
Mounting is done in an enclosure. The width of 45 mm allows for a compact installation. The terminals are clearly labeled, with supply voltage, motor connection, and signal inputs/outputs clearly separated. The connection terminals are designed for use with standard cables. The device indicators (LEDs) enable quick status monitoring during operation.
Advantages in Operation
By reducing inrush currents, the supply network is relieved. Mechanical components in the drive system experience less wear, increasing service life. The simple mounting and space-saving design enable quick integration into existing systems. The integrated network and temperature monitoring, as well as alarm outputs, ensure high operational safety. Fault diagnosis is performed via LED blink patterns, which indicate specific fault codes.