Dold 0059644, EAN: 4030641596446

Dold 0059644 semiconductor contactor AC230-480V AC50A

Dold 0059644 semiconductor contactor AC230-480V AC50A

Lieske Part No. 100153
Mfg Part No 0059644
EAN-Code 4030641596446
Manufacturer Dold
Here only 289,00 EUR
343,91 EUR incl. VAT

Further information for Dold 0059644 semiconductor contactor AC230-480V AC50A

Technical data
Analog Input Control4 - 20 mA
ApprovalsUL
Load current up to50 A
Load voltage up toAC 480 V
Number of poles1-pole
Width22,5 mm, 45 mm, 90 mm
TypeBF 9250/0_2
Temperature monitoringYes
Variant
Auxiliary voltageAC/DC 24 V
Contact equippingwithout signal contact
Control inputDC 0 - 10 V
Load currentAC 50 A
Load voltageAC 230 - 480 V
Semiconductor output1-pole
Approvals and MarkingsUL-listed C/US
VariantSelf optimising, to achieve as short as possible control periods, suitable for infrared lamps
The Dold semiconductor contactor BF9250.91/042 UH=AC/DC24V DC0-10V is an industrial semiconductor contactor with an analog control input for burst firing control of heating elements. It is used for precise temperature control in industrial applications, particularly for loads such as infrared lamps, where a fast and noiseless switching function is required. The device is designed for an auxiliary voltage of AC/DC 24 V and can switch loads up to AC 480 V and 50 A. Control is performed via an analog input with DC 0–10 V, with variants also available for DC 4–20 mA and 0–10 kΩ, enabling flexible integration into various control systems.

Applications
This device is specifically designed for use in industrial heating systems, where precise and stable temperature control is necessary. It is particularly suitable for infrared lamps, as the self-optimized impulse distribution with minimized cycle times enables rapid response to load changes. The zero-voltage switching function ensures disturbance-free switching and minimizes electrical interference in the network. The varistor protection circuit protects the device against overvoltages, increasing reliability in industrial environments.

Functions and Equipment in Detail
The contactor features temperature monitoring of the power semiconductors, which activates a red LED indicator in case of overheating. This alarm is latching and can only be reset by briefly switching off the supply voltage. Additionally, LEDs for auxiliary voltage (green), output status (yellow), and alarm (red) indicate the operating status. In case of synchronization errors or control input faults, the red LED blinks, but these messages are not latching. The control is analog, with a resolution of 5 % for this variant (BF9250.91/042), which is sufficient for precise load control.

Technology Explained Simply
The burst firing control operates on the principle of burst firing control, where the load is switched on in short, controlled pulses to precisely regulate temperature. The zero-voltage detection ensures that switching always occurs at a zero crossing of the mains voltage, increasing the lifespan of the semiconductors and avoiding network interference. The varistors protect the device against transient overvoltages, which may occur due to switching operations in the network. The current reduction at temperatures above 40 °C (0.6 A/°C at 50 A) ensures thermal safety and prevents overheating.

Compatibility and Accessories
The device is mountable on a DIN rail and complies with standards IEC/EN 60947-4-2 and IEC/EN 60947-4-3. The UL-listed C/US certification makes it suitable for use in the USA and Canada. It is designed for ohmic loads, such as those found in heaters and infrared lamps. The width is 90 mm, corresponding to the 50 A variant. For smaller loads (10 A, 25 A), variants with 22.5 mm and 45 mm width are available, but this is not applicable to this product.

Mounting and Installation
Mounting is done on a DIN rail, with recommended clearances of at least 10 mm sideways and 20 mm above/below adjacent devices to ensure sufficient cooling. Connections are clearly labeled: A1 (+) and A2 (-) for auxiliary voltage, X1 for control input, L1/N for mains connections, and T1/N for load output. The maximum relative humidity is 75 % without condensation, and the operating temperature range is between 0 °C and 40 °C, with a maximum temperature of 60 °C (with current derating factor).

Advantages in Operation
The device provides a noiseless switching function, which is important in industrial environments with high requirements for operational safety and low interference. The LED indicators allow for quick diagnosis of operating conditions and faults. The self-optimized impulse distribution ensures rapid response to load changes, especially with infrared lamps. The integrated temperature protection function and the varistor protection circuit increase the lifespan and reliability of the device. The zero-voltage switching function minimizes electrical interference and protects the load.