| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 3/e |
| Classification | For initiators |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 4 A |
| Width | 45 mm |
| Type | BH 5932 |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact |
| Nominal voltage | AC/DC 24 V |
| Response value | 20 - 26000 IPM |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | With sensor detection. PNP-input. Adjustable setting value channel 1 and 2 separated adjustable |
The Dold speed monitor BH5932.22/112 AC/DC24V 20-26000IPM is a safety-relevant monitoring switch for speed and standstill monitoring of drives in machines and plants. It is designed to prevent hazards caused by moving machine parts and is intended for use in safety-critical applications. The device features a 2-channel design and is intended for use with inductive proximity switches, with inputs designed for PNP signals. This variant includes initiator connection detection, ensuring correct sensor connections are monitored. The response value is separately adjustable for channel 1 and channel 2, covering a range of 20 to 26000 pulses per minute (IPM), enabling flexible adaptation to different drive conditions.
Applications
The BH5932 is used in industrial plants where safe monitoring of rotational and linear movements is required. Typical applications include machines with rotating parts, such as presses, milling machines, or conveyor systems, where unexpected standstill or uncontrolled speed can lead to injury or damage risks. The device is intended for use in safety-relevant control systems, particularly in plants certified according to EN ISO 13849-1 and IEC/EN 62061.
Functions and Equipment in Detail
The device features forced-guided output contacts, consisting of two closers and one opener, ensuring safe switching operations. The contacts are rated for a thermal current of up to 4 A. The initiator connection detection ensures that connected proximity switches are correctly connected, increasing the reliability of monitoring. The inputs are designed for PNP proximity switches, with the connection assignment specified for different initiator types in the datasheet. A feedback circuit (X1–X2) enables monitoring of external contacts, facilitating integration into existing safety circuits.
Technology Explained Simply
The BH5932 monitors the speed of a drive via two independent channels, each with its own adjustable response value. Signals from the proximity switches are processed via inputs In A and In B. The initiator connection detection checks whether sensors are correctly connected, preventing false alarms due to loose or missing connections. The forced-guided contacts ensure the switching operation is mechanically secured, which is required for safety-critical applications. The nominal voltage is AC/DC 24 V, enabling universal use in industrial control systems.
Compatibility and Accessories
The device is compatible with inductive proximity switches from the NA 5001, NA 5002, NA 5005, and NA 5010 series, with connection assignments varying depending on the initiator type. The terminal clamps are designed for stranded wires with 2 x 1.5 mm² (with sleeve and plastic collar DIN 46 228-1/-2/-3/-4) or 2 x 2.5 mm² (with sleeve DIN 46 228-1/-2/-3). The use of proximity switches with IP67 protection rating is recommended, as they are suitable for outdoor or dirty environments. The combination with the specified initiator types enables flexible adaptation to different requirements.
Mounting and Installation
The BH5932 has a mounting width of 45 mm and is designed for installation in standard control panels. The terminal clamps allow secure wire connections, with required cross-sections and connection types to be observed. Installation typically occurs in an enclosure, with ambient temperatures ranging from -25 °C to +70 °C. The connection assignment is detailed in the datasheet for different initiator types to ensure error-free wiring.
Operational Advantages
The BH5932 offers high safety performance with Category 3 and PL e according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061. The separate adjustability of response values for both channels enables precise adaptation to specific drive conditions. The initiator connection detection and forced-guided contacts increase reliability and prevent malfunctions. Compatibility with various proximity switches and clear connection assignment facilitate integration into existing systems. The device is designed for safety-critical applications and meets required certifications, including UL-listed C/US, TÜV, and CCC.