| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Classification | Sensorless |
| Connection | Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals |
| Forcibly guided output contacts max. | 1 NC contact, 3 NO contacts |
| Indicator contacts | 1 NO contact, 2 Semiconductor monitoring outputs |
| Measuring motor voltage max. | 690 V |
| Nominal voltage | AC, DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 5 A |
| Width | 45 mm |
| Type | LH 5946 |
| Variant |
| Auxiliary voltage | DC 24 V |
| Contact equipping | 3 NO contacts, 1 NC contact |
| Response value | 20 - 400 mV |
| Terminal type | screw terminals fixed |
| Time range | 0,2 - 6 s |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA, CCC |
The Dold standstill monitor type LH5946.48 20-400mV UH DC24V 0.2-6S is a safety-compliant, sensorless device for direction-independent monitoring of standstill in 3- and 1-phase electric motors. The device detects standstill by measuring the induced voltage in the decelerating motor. When the induction voltage drops below 20 mV, standstill is detected and the output relay is activated. The voltage threshold is adjustable in the range of 20 to 400 mV, as is the standstill time between 0.2 and 6 seconds. This adjustability enables application-specific adaptation to different motor and drive systems.
Standstill monitor with
sensorless operation eliminates the need for external sensors such as encoders or proximity switches, simplifying installation and increasing system reliability. The device is suitable for use with frequency converters, making it applicable in modern drive technologies. Wire break detection in the measurement circuit provides additional safety, as a broken measurement circuit is immediately detected.
Functions and equipment in detail include forced-guided safety output contacts: 3 NO and 1 NC, rated for AC 250 V. These contacts are intended for safe control tasks in safety systems. Additionally, the device features 2 semiconductor alarm outputs and an additional alarm output as a NO contact. LED indicators signal the motor status (standstill), wire break in the measurement circuit, and supply voltage, facilitating diagnosis during operation.
Technology explained simply is based on measuring the induced voltage in the motor. When the motor is running, rotation induces a voltage, which drops to zero at standstill. The device detects this drop and triggers the corresponding safety function. The auxiliary voltage is DC 24 V, which is a standard supply in industrial installations. The maximum motor voltage for measurement is 690 V, enabling broad applicability with various motor types. The thermal current Ith max. is 5 A, defining the contact load capacity.
Compatibility and accessories include use with frequency converters and combinability with the safety enclosure SAFEMASTER STS. The connection technology includes removable spring-clamp terminals, removable screw terminals, and fixed screw terminals, enabling flexible installation. The width is 45 mm, ensuring compatibility with standard control panels.
Mounting and installation is carried out in standard control panels with a width of 45 mm. The terminals are designed for easy and secure connection. Commissioning requires setting the voltage threshold and standstill time, which is done via the provided adjustment options. The operating instructions in the datasheet provide guidance for correct parameterization.
Operational advantages lie in the sensorless operation, which reduces the number of required components and simplifies maintenance. The fast response time and direction-independent detection increase reliability. The certifications UL-listed C/US, TÜV, UKCA, CCC, as well as safety categories up to PL e and Category 4 according to EN ISO 13849-1 and SIL 3 according to IEC/EN 62061 guarantee suitability for safety-critical applications. The LED indicators enable quick status monitoring during operation.
The device is designed as a
2-channel unit, enabling simultaneous monitoring of two motors or drives. The classification as
sensorless and the
forced-guided output contacts are key characteristics for the safety function. The
rated voltage is designed for AC and DC, increasing flexibility in various installations. The
certifications include UL, TÜV, UKCA, and CCC, ensuring international usability.