Dold 0058960, EAN: 4030641589608

Dold 0058960 PH9260.91/100 AC48-600V AC50A semiconductor relay UH=AC/DC18-36V

Dold 0058960 PH9260.91/100 AC48-600V AC50A semiconductor relay UH=AC/DC18-36V

Lieske Part No. 100134
Mfg Part No 0058960
EAN-Code 4030641589608
Manufacturer Dold
Here only 87,39 EUR
103,99 EUR incl. VAT

Further information for Dold 0058960 PH9260.91/100 AC48-600V AC50A semiconductor relay UH=AC/DC18-36V

Technical data
Load current up to125 A
Load voltage up toAC 600 V
Number of poles1-pole
On/Off Input ControlAC/DC, DC
Width45 mm
TypePH 9260
Variant
Control voltageAC/DC 18 - 36 V
Load currentAC 50 A
Load voltageAC 48 - 600 V
Semiconductor output1-pole
VariantSwitching at zero crossing. With heigh I2t-value. Without heat sink.
The Dold semiconductor relay PH9260.91/100 AC48-600V AC50A is an AC semiconductor relay/contactor designed for use in industrial applications. It is used for wear-free and noiseless switching of loads such as heaters, motors, valves, and lighting systems. The device is compliant with IEC/EN 60947-4-3 and features a width of 45 mm, making it suitable for mounting on a DIN rail. Control is achieved via a control voltage of AC/DC 18–36 V, with the relay designed as zero-voltage switching to minimize switching disturbances and current surges.

Applications
This semiconductor relay is intended for use in machine building and manufacturing technology, particularly in injection molding machines, packaging machines, soldering systems, and the food industry. The zero-voltage switching function makes it especially suitable for applications requiring gentle and disturbance-free switching, such as controlling heating circuits or motors. Alternatively, a peak-voltage switching variant is available, specifically developed for switching transformers to avoid high inrush current.

Functions and Equipment in Detail
The device is based on DCB technology (Direct-Copper-Bonding process), which enables excellent heat transfer and thus reduces thermal stress. It consists of two antiparallel-connected thyristors responsible for the switching function. The LED status indicator signals the state of the control input and facilitates diagnostics. The box terminals allow for secure and easy connection of wires. The insulation voltage is 4000 V, ensuring high electrical safety. The peak blocking voltage is 1200 V or 1600 V, depending on the version.

Technology Explained Simply
The relay switches the load on at the next zero crossing of the sinusoidal mains voltage as soon as the control voltage is applied. When the control voltage is removed, the load is switched off at the next zero crossing of the load current. This prevents spark generation and reduces electromagnetic interference. The I2t value of up to 18000 A²s enables high surge current resistance, which is important in case of sudden load changes or short-circuit conditions. The load voltage range is AC 48–600 V, and the load current is AC 50 A for this variant, although the device is designed for load currents up to 125 A. The junction temperature must not exceed 125 °C, which is ensured by the DCB technology and heat dissipation.

Compatibility and Accessories
The device is designed as zero-voltage switching, with an optional peak-voltage switching variant available. It can be equipped with a heat sink that clips onto the DIN rail to optimize heat dissipation. Optionally, an over-temperature protection can be integrated, realized via a temperature-limit switch (normally open) that can be inserted into a designated pocket on the device. For thermal protection, a temperature-limit switch of type UCHIYA UP62–100 can be used. The touch protection class IP20 at the terminals protects against contact with live parts.

Mounting and Installation
The relay is mounted on a DIN rail, with its width of 45 mm allowing for compact placement. The box terminals allow for easy and secure wire connections. Mounting requires no additional tools, as the terminals are connected directly. The operating temperature range is from -20 °C to +40 °C, with storage up to +80 °C being possible.

Operational Advantages
The semiconductor relay offers wear-free operation, as there are no mechanical contacts. This eliminates maintenance requirements and results in a significantly longer service life compared to mechanical relays. The low forward voltage drop (approximately 1.2–1.4 V at rated current) ensures low power loss. Electromagnetic compatibility (EMC) is specified according to IEC/EN 61000-6-4 and IEC/EN 61000-4-1, minimizing disturbances during operation. RF emissions can be optionally reduced to ensure compliance with EMC regulations. The heat dissipation via DCB technology ensures reliable operation even under high load conditions.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/100134
qrcode für Dold 0058960 PH9260.91/100 AC48-600V AC50A semiconductor relay UH=AC/DC18-36V