Dold 0058904, EAN: 4030641589042

Dold 0058904 semiconductor contactor 3xAC 15A

Dold 0058904 semiconductor contactor 3xAC 15A

Lieske Part No. 1001449
Mfg Part No 0058904
EAN-Code 4030641589042
Manufacturer Dold
Here only 377,03 EUR
448,67 EUR incl. VAT

Further information for Dold 0058904 semiconductor contactor 3xAC 15A

Technical data
ApprovalsUL
Load current up to50 A
Load voltage up toAC 480 V
Number of poles1-pole, 2-pole, 3-pole
On/Off Input ControlAC/DC, DC
Width22,5 mm, 45 mm, 90 mm
TypeBF 9250
Signalling outputYes
Temperature monitoringYes
Variant
Auxiliary voltageAC/DC 24 V
Contact equippingwith signal contact
Load current3 x AC 15 A
Load voltageAC 24 - 480 V
Semiconductor output3-pole
Approvals and MarkingsUL-listed C/US
VariantSwitching at zero crossing.
The Dold semiconductor contactor BF9250.03 UH=AC/DC24V 3xAC 15A is an industrial power semiconductor switch designed for frequent and noiseless switching of electrical loads in industrial plants. It is used to control heating systems, motors, valves, and lighting systems, with switching operations performed without mechanical contacts and thus without wear. The device is configured as a 3-pole variant and features a control voltage of AC/DC 24 V. The load voltage is AC 24 to 480 V, and the load current is 3 x AC 15 A. Switching is zero-voltage switching, meaning the switch operates the load at the moment of zero crossing of the alternating voltage to minimize electrical interference and sparking. The width is 90 mm, making it suitable for use in standard DIN control panels.

Applications
This semiconductor contactor is intended for use in industrial control and regulation systems, particularly in plants requiring high switching frequency and noiseless operation. It is suitable for applications in manufacturing industry, building automation, process control, and installations with high requirements for operational safety. Zero-voltage switching reduces electromagnetic compatibility (EMC) and extends the service life of connected devices. Protection circuitry using varistors provides additional protection against overvoltage.

Functions and Equipment in Detail
The device features an integrated alarm output that signals in case of operational faults or overloads. Temperature monitoring protects the power semiconductors from overheating and ensures safe operation. When a critical temperature is reached, the alarm output is activated, enabling early response to malfunctions. Control is performed via a digital input that can process both AC/DC and DC signals. This makes the device particularly suitable for control by programmable logic controllers (PLC). Terminal markings include control and operating voltage (A1, A2, X1), alarm output (18), normally open contact (11, 12), and supply and load connections (L1, L2, L3, T1, T2, T3).

Technology Explained Simply
The semiconductor contactor operates using power semiconductors that switch electrical loads without mechanical movement. Zero-voltage switching ensures that the switch operates the load at the moment the voltage reaches zero, minimizing sparking and electromagnetic interference. Integrated temperature monitoring monitors the heat development of the semiconductors and disconnects the output when a critical temperature is reached. Varistors protect the device against transient overvoltages caused by switching operations or network disturbances. The width of 90 mm allows mounting on a DIN rail, ensuring easy integration into existing control panels.

Compatibility and Accessories
The device is certified according to standards IEC/EN 60947-4-2 and IEC/EN 60947-4-3, guaranteeing compliance with safety and functional requirements for semiconductor contactors. It is UL-listed C/US, confirming approval for use in the USA and Canada. The width of 90 mm allows mounting in standard DIN control panels. Control via input X1 with low current consumption makes the device compatible with PLC systems. Combination with other BF 9250 models in different widths (22.5 mm, 45 mm, 90 mm) enables flexible arrangement in control panels.

Mounting and Installation
The semiconductor contactor is mounted on a DIN rail, with the width of 90 mm enabling placement in standard control panels. Connections are made via terminals designed for wiring. Control is performed via connections A1/A2 or X1, with the control input X1 having low current consumption. Load connections T1, T2, T3 are intended for connection to the electrical load. Supply connections L1, L2, L3 are for providing operating voltage. Mounting requires no additional tools, as the device snaps onto the rail.

Advantages in Operation
The semiconductor contactor offers high switching frequency without mechanical wear, increasing service life and extending maintenance intervals. Zero-voltage switching reduces electromagnetic interference and prevents sparking. Integrated temperature monitoring and alarm output ensure safe operation and enable early fault detection. The low current consumption of control input X1 makes the device particularly suitable for control by PLC systems. Certification according to IEC/EN 60947-4-2 and IEC/EN 60947-4-3, as well as UL listing, guarantee safety and reliability in industrial applications.