Further information for Dold 0058822 semiconductor contactor AC230-480V AC50A
Technical data
Analog Input Control
4 - 20 mA
Approvals
UL
Load current up to
50 A
Load voltage up to
AC 480 V
Number of poles
1-pole
Width
22,5 mm, 45 mm, 90 mm
Type
BF 9250/0_2
Temperature monitoring
Variant
Auxiliary voltage
AC/DC 24 V
Contact equipping
without signal contact
Control input
DC 0 - 10 V
Load current
AC 50 A
Load voltage
AC 230 - 480 V
Semiconductor output
1-pole
Approvals and Markings
UL-listed C/US
Variant
Output control with fixed period of 64 cycles
The Dold semiconductor contactor BF9250.91/002 UH=AC/DC24V DC0-10V is an industrial power semiconductor for precise temperature control in systems with heating elements. It serves as an impulse packet control for resistive loads and enables fast and noiseless switching without mechanical contacts. The device is designed for use in industrial control and regulation systems where precise load control via an analog input is required. Control is achieved via an analog input, which can be configured as voltage (DC 0–10 V) or current (DC 4–20 mA). The impulse control operates through a linear distribution of impulses over 64 cycles, enabling a high resolution of 1.5625 %. The control is zero-voltage switching, minimizing switching sparks and interference. The auxiliary voltage is AC/DC 24 V, allowing flexible integration into existing control systems.
Applications include temperature control in industrial heating systems, such as drying plants, ovens, or heating boilers. The device is rated for load voltages of AC 230 to 480 V and load currents up to AC 50 A. The temperature protection function of the power semiconductor protects the device from overheating, with a LED indicator lighting red in case of overtemperature. This message is latching and requires a brief interruption of the supply voltage to reset. Additional LED indicators provide information on synchronization errors or faults in the control input. The operating mode is continuous duty, with current derating occurring above 40 °C: at 50 A, the current reduces by 0.6 A per degree Celsius.
Functions and equipment in detail include a varistor protection circuit for protection against overvoltages. The LED indicators for auxiliary voltage (green), output status (yellow), and alarm (red) enable visual monitoring of the operating state. The control is invertible, meaning the output power decreases as the input signal increases. The terminal connections are designed for connection to mains (L1, N) and load (T1, N). The width is 90 mm, corresponding to the maximum rated current class of 50 A. The device is snap-on mountable on DIN rail, enabling easy installation in enclosures.
Technology explained simply is based on impulse packet control, where the load is switched on in short, regulated pulses. The pulse width is controlled via the analog input, allowing precise regulation of average power and thus the temperature of the load. The zero-voltage detection ensures switching always occurs at the zero crossing of the AC voltage, increasing the lifespan of the semiconductors and minimizing interference. The varistors protect the device against transient overvoltages caused by network disturbances or load switching operations. The temperature protection function monitors the temperature of the power semiconductors and reduces the load current in case of overtemperature to prevent damage.
Compatibility and accessories refer to use with control devices providing an analog output (DC 0–10 V or DC 4–20 mA). Conformity with standards IEC/EN 60947-4-2 and IEC/EN 60947-4-3 ensures safety and reliability in industrial applications. The UL-listed C/US certification enables use in the USA and Canada. The device is designed for resistive loads, such as heating strips, heating ovens, or infrared lamps. The installation recommendation specifies clearances of 20 mm above and below and 10 mm laterally from the cable duct to ensure sufficient cooling.
Mounting and installation is performed by snapping onto a DIN rail. Connections are made via the designated terminals for mains (L1, N) and load (T1, N). The supply voltage is connected to A1 (+) and A2 (-). Control is achieved via connection X1. The maximum air humidity is 75 % without condensation, and the operating temperature range is between 0 and 40 °C. Current derating is required above 60 °C.
Operational advantages include high control precision due to impulse packet control with 64 cycles, noiseless and wear-free switching, and integrated fault detection via LED indicators. Zero-voltage switching reduces electromagnetic interference and extends the lifespan of the semiconductors. The integrated temperature protection function increases operational safety. DIN rail mounting enables quick and flexible installation in existing enclosures. The UL-listed C/US certification expands the application scope into North American markets.