| Technical data |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals |
| Output contacts max. | 1 NC contact, 3 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Safety integrity level according to EN 574 | lll C |
| Safety integrity level according to EN ISO 13851 | lll C |
| Thermal current Ith max. | 5 A |
| Width | 22,5 mm |
| Type | LG 5933 |
| Variant |
| Contact equipping | 3 NO contacts, 1 NC contact |
| Nominal voltage | DC 24 V |
| Terminal type | pluggable terminal blocks with cage clamp terminals |
| Approvals and Markings | TÜV, UKCA, CCC |
The Dold safety relay type LG5933.48PC DC24V is a ready-to-connect device for the safe control of working machines, particularly in applications with two-hand controls. It is used for safety-oriented enabling and interruption of a safety circuit to protect personnel and machines from hazardous movements such as closing operations in metalworking presses. The device is designed for use in industrial environments where high safety integrity is required.
Applications
This safety relay is used in machine controls where two-hand operation is required to prevent unintended or uncontrolled machine movements. Typical applications include presses, cutting machines, or other machine tools with hazardous closing movements. The function enables a compact and cost-efficient implementation of safety controls, as conventional contactor controls can be eliminated.
Functions and equipment in detail
The device features contact configuration with 3 normally open (NO) contacts and 1 normally closed (NC) contact at the output, enabling flexible connection to additional safety components. The inputs are designed for two switches, where each can be connected with one NC and one NO contact. The relay’s function is based on monitoring the input signals: the safety circuit is only enabled when both switches are activated simultaneously. If an input or a feedback circuit (Y1–Y2) is interrupted, the output is immediately deactivated. The device provides overvoltage and short-circuit protection to enhance the reliability of the control.
Technology explained simply
The safety relay operates at a nominal voltage of DC 24 V and is designed for a thermal current load capacity of up to 5 A. The connection technology includes removable terminal blocks with spring-cage terminals, enabling quick installation and maintenance. The width is 22.5 mm, allowing compact placement in standard control panels. The spring-cage terminals are suitable for conductor cross-sections up to 2.5 mm² solid (DIN 46228-1/-2/-3/-4) or 1.5 mm² stranded wire with ferrule and plastic collar. The removable terminal blocks facilitate device replacement without removing the wiring.
Compatibility and accessories
The device is designed for use with two-hand controls and can monitor external contactors via feedback circuits (Y1–Y2) to enable contact multiplication or amplification. Certifications TÜV, UKCA, and CCC confirm compliance with European and international safety standards. The safety levels correspond to Type III C according to EN ISO 13851 and EN 574, ensuring high reliability in critical applications. The safety integrity is certified with Performance Level (PL) e and Category 4 according to EN ISO 13849-1, as well as SIL 3 according to IEC/EN 62061 and EN 61508.
Mounting and installation
Mounting is performed in standard control panels with a width of 22.5 mm. The removable spring-cage terminals allow for quick and secure connection of the wiring. Installation must follow the manufacturer’s technical instructions, ensuring correct wiring of the inputs (two switches) and outputs (3 NO, 1 NC). The feedback circuits (Y1–Y2) are intended for monitoring external contactors and must be connected accordingly.
Advantages in operation
The safety relay offers a compact, maintenance-friendly, and reliable solution for machine safety control. The removable terminal blocks allow for quick replacement without disconnecting the wiring. The integrated monitoring function for external contactors reduces the number of required components and decreases failure susceptibility. The certifications and safety levels guarantee use in critical applications where personnel and machine safety are paramount. The use of DC 24 V is widely adopted in industrial electrical engineering and enables easy integration into existing control systems.