Further information for Dold 0057519 BA7924.21/002/61 DC24V 4S delay module

Technical data
1- / 2-channel1
ApprovalsUL-Recognized
Cat. / PL acc. to EN ISO 13849-13/d
ConnectionScrew terminals
Output contacts max.1 NC contact, 1 NO contact
SIL CL acc. to IEC/EN 620612
SIL acc. to IEC/EN 620612
Thermal current Ith max.8 A
Time delay max.30 s
Width45 mm
TypeBA 7924
Variant
Contact equipping1 NC contact, 1 NO contact
Nominal voltageDC 24 V
Time range4 s
Approvals and MarkingsUL-rec. C/US, TÜV, CCC
Variant2 timing circuit, fixed time
The Dold delay module BA7924.21/002/61 DC24V 4S is an industrial safety device for implementing delayed disconnections in control and protection systems. It serves as a drop-out delayed module, operating without auxiliary voltage, and can be used in combination with suitable switching devices or controls in safety-related applications. The width is 45 mm, making it suitable for standard distribution boxes. The device features a forced-guided contact configuration with one normally open contact and one normally closed contact, ensuring a secure switching position. The time delay is fixed at 4 seconds, with a maximum delay of up to 30 seconds depending on the variant. The rated voltage is DC 24 V, making it suitable for typical industrial control systems.

Applications
This module is designed for use in safety-critical installations, for example in automation technology, machine controls, or in systems requiring controlled shutdowns. It can be used in combination with suitable switching devices or controls up to PL d and Category 3 according to EN ISO 13849-1, as well as up to SIL 2 according to IEC/EN 62061. The drop-out delayed function allows the output to remain active for a defined period after the input signal is switched off, before returning to the rest state. This is particularly useful for safely shutting down mechanical or electrical loads or ensuring a process is fully completed before the next step begins.

Functions and Equipment in Detail
The device features two separate time circuits that can be used for redundant safety functions. The output contacts are forced-guided, meaning the normally open and normally closed contacts are mechanically coupled, ensuring a secure switching state. The switching position indicator allows for visual inspection of the current contact status. The connection technology uses screw terminals, ensuring a secure and reliable connection. The maximum thermal current rating is 8 A, sufficient for most industrial applications.

Technology Explained Simply
The delay function is implemented via an internal timing mechanism that keeps the output contacts active for the set time (here 4 seconds) after the input signal is switched off. The drop-out delayed function means the output does not immediately return to the rest state, but only after the delay time has elapsed. This is particularly important in applications where immediate shutdown could cause damage or hazards. The forced guidance of contacts ensures that opening the normally closed contact simultaneously causes the normally open contact to close, enabling a safe and redundant switching function. The approvals UL-rec. C/US, TÜV, and CCC confirm compliance with international safety standards.

Compatibility and Accessories
The module is designed for use in standard distribution boxes and can be used in combination with suitable switching devices or controls. It is available in various variants, including with one or two separate time circuits, and with adjustable or fixed time delays. The width of 45 mm allows for mounting in standard distribution boxes. Use in I-distribution enclosures is also possible, though this requires a special variant. Compatibility with safety controls is provided, provided these meet the required safety category requirements.

Mounting and Installation
Mounting is done in standard distribution boxes with a width of 45 mm. The connection terminals are designed for cable connections, with screw terminals ensuring a secure connection. Installation does not require special tools, but proper wiring according to technical specifications is required. The switching position indicator allows for easy visual inspection of the operating status. The devices are designed for industrial environments and meet safety technology requirements.

Operational Advantages
The drop-out delayed function enables controlled shutdowns, which are required in many industrial applications. The forced guidance of contacts ensures high safety, as a failure in one contact automatically affects the other. The switching position indicator simplifies maintenance and diagnostics. The approvals according to EN ISO 13849-1 and IEC/EN 62061 confirm suitability for safety-critical applications. The maximum delay time of 30 seconds offers flexibility in adapting to various process requirements. The width of 45 mm allows for compact mounting in standard distribution boxes.

Safety Technology Specifications
The device meets safety function requirements up to PL d and Category 3 according to EN ISO 13849-1, as well as up to SIL 2 according to IEC/EN 62061. These ratings confirm suitability for safety-critical applications requiring high reliability and fault tolerance. The approvals UL-rec. C/US, TÜV, and CCC confirm compliance with international safety standards. The thermal current rating of 8 A is sufficient for most industrial applications. The time delay is fixed at 4 seconds, with a maximum delay of up to 30 seconds depending on the variant.

Connection Technology and Mounting
The connection technology uses screw terminals, ensuring a secure and reliable connection. Mounting is done in standard distribution boxes with a width of 45 mm. The devices are designed for industrial environments and meet safety technology requirements. The switching position indicator allows for easy visual inspection of the operating status. Installation does not require special tools, but proper wiring according to technical specifications is required.

Approvals and Markings
The device is certified with UL-rec. C/US, TÜV, and CCC approvals, confirming compliance with international safety standards. The safety technology specifications include PL d and Category 3 according to EN ISO 13849-1, as well as SIL 2 according to IEC/EN 62061. These ratings confirm suitability for safety-critical applications requiring high reliability and fault tolerance. The approvals UL-rec. C/US, TÜV, and CCC confirm compliance with international safety standards.

Functions and Equipment in Detail
The device features two separate time circuits that can be used for redundant safety functions. The output contacts are forced-guided, meaning the normally open and normally closed contacts are mechanically coupled, ensuring a secure switching state. The switching position indicator allows for visual inspection of the current contact status. The connection technology uses screw terminals, ensuring a secure and reliable connection. The maximum thermal current rating is 8 A, sufficient for most industrial applications.

Compatibility and Accessories
The module is designed for use in standard distribution boxes and can be used in combination with suitable switching devices or controls. It is available in various variants, including with one or two separate time circuits, and with adjustable or fixed time delays. The width of 45 mm allows for mounting in standard distribution boxes. Use in I-distribution enclosures is also possible, though this requires a special variant. Compatibility with safety controls is provided, provided these meet the required safety category requirements.

Mounting and Installation
Mounting is done in standard distribution boxes with a width of 45 mm. The connection terminals are designed for cable connections, with screw terminals ensuring a secure connection. Installation does not require special tools, but proper wiring according to technical specifications is required. The switching position indicator allows for easy visual inspection of the operating status. The devices are designed for industrial environments and meet safety technology requirements.

Operational Advantages
The drop-out delayed function enables controlled shutdowns, which are required in many industrial applications. The forced guidance of contacts ensures high safety, as a failure in one contact automatically affects the other. The switching position indicator simplifies maintenance and diagnostics. The approvals according to EN ISO 13849-1 and IEC/EN 62061 confirm suitability for safety-critical applications. The maximum delay time of 30 seconds offers flexibility in adapting to various process requirements. The width of 45 mm allows for compact mounting in standard distribution boxes.

Safety Technology Specifications
The device meets safety function requirements up to PL d and Category 3 according to EN ISO 13849-1, as well as up to SIL 2 according to IEC/EN 62061. These ratings confirm suitability for safety-critical applications requiring high reliability and fault tolerance. The approvals UL-rec. C/US, TÜV, and CCC confirm compliance with international safety standards. The thermal current rating of 8 A is sufficient for most industrial applications. The time delay is fixed at 4 seconds, with a maximum delay of up to 30 seconds depending on the variant.

Connection Technology and Mounting
The connection technology uses screw terminals, ensuring a secure and reliable connection. Mounting is done in standard distribution boxes with a width of 45 mm. The devices are designed for industrial environments and meet safety technology requirements. The switching position indicator allows for easy visual inspection of the operating status. Installation does not require special tools, but proper wiring according to technical specifications is required.

Approvals and Markings
The device is certified with UL-rec. C/US, TÜV, and CCC approvals, confirming compliance with international safety standards. The safety technology specifications include PL d and Category 3 according to EN ISO 13849-1, as well as SIL 2 according to IEC/EN 62061. These ratings confirm suitability for safety-critical applications requiring high reliability and fault tolerance. The approvals UL-rec. C/US, TÜV, and CCC confirm compliance with international safety standards.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1002384
qrcode für Dold 0057519 BA7924.21/002/61 DC24V 4S delay module