| Technical data |
| Approvals | UL |
| Load current up to | 50 A |
| Load voltage up to | AC 480 V |
| Number of poles | 1-pole, 2-pole, 3-pole |
| On/Off Input Control | DC |
| Width | 22,5 mm, 45 mm, 90 mm |
| Type | BF 9250/_ _8 |
| Variant |
| Auxiliary voltage | DC 7 - 32 V |
| Contact equipping | without signal contact |
| Load current | 2 x AC 15 A |
| Load voltage | AC 24 - 240 V |
| Semiconductor output | 2-pole |
| Approvals and Markings | UL-listed C/US |
| Variant | Switching at zero crossing. |
The Dold semiconductor contactor BF9250.92/008 is a 2-pole electronic switching device for frequency-stable and noiseless control of AC loads. It is operated with an auxiliary voltage in the range DC 7 to 32 V and is designed for load currents of 15 A per pole at a load voltage of AC 24 to 240 V. The device is zero-voltage switching, meaning that the switching operation occurs at the zero crossing of the alternating voltage to minimize electrical interference and sparking. Control is digital via a direct voltage, making it suitable for use in industrial control systems. The width is 45 mm, making it suitable for mounting on a DIN rail.
Applications
This semiconductor contactor is designed for use in industrial and technical installations where frequent and disturbance-free switching of loads is required. It is particularly suitable for controlling heating systems, motors, valves, and lighting systems. The zero-voltage switching reduces electromagnetic interference and extends the service life of connected devices. The maximum load voltage is AC 480 V, with load currents varying depending on ambient temperature and width. At an ambient temperature of 40 °C, the load current for the 2-pole version is 2 x AC 15 A.
Functions and Equipment in Detail
The device features a semiconductor output with 2-pole configuration and is supplied without a signaling output. Switching is performed via an integrated trigger pulse generator, which initiates switching operations at the zero crossing of the alternating voltage. The turn-on and turn-off delay is ≤ 1 ms plus 1/2 cycle of the mains voltage. Protection is provided by varistors, which protect against overvoltage. The connection terminals are clearly labeled: A1/A2 for control voltage, L1/L2 for mains connections, and T1/T2 for load outputs.
Technology Explained Simply
The semiconductor contactor operates without mechanical contacts, which increases its service life and eliminates noise during switching. Control is via a direct voltage (DC), which activates the device. Zero-voltage switching ensures that current flow begins or ends at the moment of voltage zero crossing, minimizing network interference. Power loss is calculated using the formula P = 1.2 [V] x I_eff. [A] / k [W], where k is the form factor and is 1.11 for sinusoidal current. The maximum ambient temperature is 40 °C; at higher temperatures, current reduction is required.
Compatibility and Accessories
The device is compliant with IEC/EN 60947-4-2 and IEC/EN 60947-4-3 standards and carries the UL-listed C/US certification. It is designed for use in installations with AC loads up to 480 V. The width of 45 mm allows mounting on a DIN rail. For higher switching currents, a variant with a high I²t value of the semiconductor (variant /1_8) is available. Protection is provided by varistors with a voltage rating of AC 510 V.
Mounting and Installation
The device is designed for horizontal installation and can be mounted directly onto a DIN rail. The connection terminals are intended for connection to wires. The operating temperature range is from 0 °C to 40 °C, and the storage temperature range is from -20 °C to +80 °C. The maximum operating temperature is 60 °C; if this exceeds the rated temperature, current reduction is required.
Advantages in Operation
The semiconductor contactor offers high operational reliability due to zero-voltage switching, which minimizes network interference. The noiseless switching is particularly advantageous in sensitive environments. The long service life, due to the absence of mechanical contacts, reduces maintenance and replacement intervals. The UL-listed C/US certification and compliance with IEC/EN 60947-4-2 and -4-3 standards ensure suitability for various applications. The integrated protection with varistors increases device reliability during voltage surges.