Dold 0057419, EAN: 4030641574192

Dold 0057419 semiconductor contactor AC24-240V

Dold 0057419 semiconductor contactor AC24-240V

Lieske Part No. 1001407
Mfg Part No 0057419
EAN-Code 4030641574192
Manufacturer Dold
Here only 155,80 EUR
185,40 EUR incl. VAT

Further information for Dold 0057419 semiconductor contactor AC24-240V

Technical data
ApprovalsUL
Load current up to50 A
Load voltage up toAC 480 V
Number of poles1-pole, 2-pole, 3-pole
On/Off Input ControlDC
Width22,5 mm, 45 mm, 90 mm
TypeBF 9250/_ _8
Variant
Auxiliary voltageDC 4 - 32 V
Contact equippingwithout signal contact
Load currentAC 25 A
Load voltageAC 24 - 480 V
Semiconductor output1-pole
Approvals and MarkingsUL-listed C/US
VariantSwitching at zero crossing.
The Dold semiconductor contactor BF9250.91/008 UH=DC4-32V AC25A is a 1-pole electronic switching device for use in industrial applications. It is designed for frequent and noiseless switching of loads such as heaters, motors, valves, and lighting. The device operates as a semiconductor contactor with zero-voltage switching behavior, meaning that the switching process occurs at the zero crossing of the alternating voltage to minimize arcing and electrical interference. Control is achieved via a digital control voltage in the range DC 4 to 32 V, making it suitable for applications with electronic control. The load voltage range is AC 24 to 480 V, and the maximum load current is AC 25 A at an ambient temperature of 40 °C. At 25 °C, a load current of 30 A is possible, with current capacity varying depending on width and cooling. The width is 45 mm, enabling compact mounting on DIN rail. The devices are specified according to IEC/EN 60947-4-2 and IEC/EN 60947-4-3 and carry the UL-listed C/US approval, enabling use in certain markets, particularly in North America.

Applications
This semiconductor contactor is designed for use in industrial and technical installations where reliable, interference-free, and noiseless switching is required. Typical applications include control of heating systems, electric motors, pneumatic or hydraulic valves, and lighting installations. Zero-voltage switching reduces electromagnetic compatibility (EMC) interference and extends the lifespan of loads, especially with inductive loads. The devices are designed for continuous operation and can be operated in environments with temperatures from 0 to 40 °C. The maximum operating temperature is 60 °C, with current derating required at higher temperatures.

Functions and Features in Detail
The device includes an integrated zero-crossing detection to synchronize switching. The turn-on and turn-off delay is each ≤ 1 ms plus 1/2 cycle of the mains voltage, which is approximately 10 ms at 50 Hz. The circuit is protected with varistors to limit overvoltages in the network. The terminal connections are clearly labeled: A1/A2 for control voltage, L1/L2/L3 for mains connections, and T1/T2/T3 for load outputs. A green LED indicates that voltage is present at terminals A1/A2. The devices are snap-mounted onto DIN rail, enabling quick and secure installation in enclosures.

Technology Explained Simply
The semiconductor contactor operates without mechanical contacts, using semiconductor components such as thyristors or triacs that are electronically controlled. This eliminates mechanical wear, resulting in high service life and low maintenance. The zero-voltage switching ensures that current flow begins or ends at the zero crossing of the alternating voltage, minimizing switching interference. Current derating at higher temperatures occurs linearly, with values varying depending on heatsink size. At 40 °C, the maximum permissible load current is 25 A; at 25 °C, it is 30 A. The peak blocking voltage is ±1200 Vp, enhancing safety during voltage surges. The leakage current in the blocked state is approximately 1.0 mA, which is relevant for operational safety.

Compatibility and Accessories
The device is available in various configurations, including 1-, 2-, and 3-pole versions. Widths vary between 22.5 mm, 45 mm, and 90 mm, with the described version being 45 mm. Optional variants with high I²t value of the semiconductor are available for high switching currents (variant /1_8). The devices must be protected with cylindrical fuses (e.g., 10 x 38), with the exact fuse size varying depending on load current and device type. The UL-listed C/US approval enables use in the USA and Canada.

Mounting and Installation
Mounting is done by snapping onto a DIN rail, with the installation position required to be horizontal. The cooling fins must be oriented vertically to ensure optimal heat dissipation. Connections are clearly labeled: control voltage is connected to A1/A2, load to T1/T2/T3, and mains connections L1/L2/L3 to the supply network. The devices are designed for continuous operation and require no additional cooling, provided ambient temperature remains within the specified range.

Operational Advantages
The semiconductor contactor offers high operational safety due to zero-voltage switching, which reduces switching interference and load wear. The noiseless switching is particularly advantageous in sensitive environments. The long service life and low maintenance frequency reduce operating costs. Compatibility with digital controls and easy DIN rail mounting simplify integration into existing systems. The UL-listed C/US approval expands the application range in international markets.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1001407
qrcode für Dold 0057419 semiconductor contactor AC24-240V