Dold 0057253, EAN: 4030641572532

Dold 0057253 motor brake unit BN9034/0100 25A 400V

Dold 0057253 motor brake unit BN9034/0100 25A 400V

Lieske Part No. 1001868
Mfg Part No 0057253
EAN-Code 4030641572532
Manufacturer Dold
Here only 637,56 EUR
758,70 EUR incl. VAT

Further information for Dold 0057253 motor brake unit BN9034/0100 25A 400V

Technical data
Braking current adjustable up to max.25 A
Braking time adjustable up to max.15 s
Width100 mm
TypeBN 9034
Automatic standstill monitoringYes
Signalling outputYes
Temperature monitoringYes
Variant
Auxiliary voltageWithout
Braking current25 A
Braking time15 s
Nominal voltageAC 400 V
Approvals and MarkingsUKCA
VariantWith output relay for standstill indication
The electronic motor brake device BN9034/0100 from Dold belongs to the MINISTOP series and is designed for wear-free braking of three-phase and alternating current asynchronous motors. It is intended for drives that must be reliably braked for safety and functional reasons, for example in sawmills, centrifuges, woodworking machines, textile machines or conveyor systems. The device enables precise control of the braking process and reduces coast-down times, thereby increasing safety and operational efficiency.

Applications
This brake device is used in industrial plants where controlled and rapid stopping of the motor is required. Typical applications include machines that must not coast freely after switching off, to avoid accidents or production losses. The application is independent of motor power, as long as the technical specifications of the device are met. The width of 100 mm allows compact mounting on a 35 mm standard rail, simplifying installation in existing control panels.

Functions and Equipment in Detail
The device operates with DC braking via a single-phase rectifier and generates a braking DC voltage, which is applied to the stator winding of the motor via terminals T1 and T2. The braking current is adjustable up to a maximum of 25 A, with a maximum braking time of 15 seconds. Braking is activated after switching off the motor contactor via an integrated brake contactor. The braking time starts after a safety delay period, ensuring a safe interval from motor switch-off.

Technology Explained Simply
Standstill monitoring is automatic: as soon as the motor stops, the braking current is switched off. In case of standstill-dependent braking, a potential-free alarm contact signals if the motor has not come to a stop within the maximum braking time of 15 seconds. This enables quick fault detection. Temperature monitoring is implemented via an optional thermistor (PTC), connected to terminals X14 and X15. The device display includes an LED ready", which lights up when supply voltage is present, and an LED "I, which activates when braking current is flowing.

Compatibility and Accessories
The device is designed for a rated voltage of AC 400 V, with an optional voltage range of AC 200 to 575 V available. The frequency is 50/60 Hz. The auxiliary voltage is not present in this variant. The device complies with the standard IEC/EN 60947-4-2 and is marked with the UKCA symbol. It is suitable for motors up to 5.5 kW at 400 V. The connection terminals are designed for a maximum cross-section of 2 x 2.5 mm² per terminal, with a maximum tightening torque of 0.8 Nm.

Mounting and Installation
The device is mounted on a 35 mm standard rail. The supply voltage is connected to terminals L1 and L2, with the interlock contact for the motor contactor connected via X5 and X6. Start is initiated via the start contact at X3 and X4, connected to the normally open contact of the motor contactor. The braking DC voltage is taken from T1 and T2. Terminals X7 and X8 are for fault signaling, X16 and X17 for standstill signaling. The device display indicates the operating status.

Advantages in Operation
The motor brake device BN9034/0100 is wear-free and maintenance-free, reducing operating costs. The adjustable braking time and adjustable braking current allow adaptation to different drive conditions. Automatic standstill monitoring and integrated temperature monitoring increase safety. Mounting on the standard rail and compatibility with existing control panels simplify installation. The operating temperature range is between 0 °C and +45 °C, and the storage temperature range is between -25 °C and +75 °C. The device is designed for indoor use with protection rating IP 20.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1001868
qrcode für Dold 0057253 motor brake unit BN9034/0100 25A 400V