| Technical data |
| 1- / 2-channel | 2 |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 3/e |
| Classification | For initiators |
| Forcibly guided output contacts max. | 1 NC contact, 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Thermal current Ith max. | 4 A |
| Width | 45 mm |
| Type | BH 5932 |
| Variant |
| Contact equipping | 2 NO contacts, 1 NC contact |
| Nominal voltage | AC/DC 24 V |
| Response value | 3000 IPM |
| Approvals and Markings | UL-listed C/US, TÜV, CCC |
| Variant | Without sensor detection. PNP-input. Fixed setting value |
The Dold speed monitor BH5932.22/010/61 is a safety-relevant monitoring switch for speed and standstill monitoring in industrial drive systems. The device is used to detect machine movements, particularly in plants where moving parts may pose a hazard to personnel or machinery. It is designed for use in safety-critical applications where reliable and error-free operation is essential.
Applications
The BH5932 is used in machines and plants where monitoring of rotational and linear movements is required. Typical applications include drives in the manufacturing industry, packaging technology, conveyor systems, or automation technology, where safe shutdown is necessary in case of unwanted movement or standstill. The device is designed for initiators, i.e. sensors that detect movement and transmit the signal to the device.
Functions and equipment in detail
The device features a fixed setpoint of 3000 IPM (impulses per minute), which defines the speed limit at which a response is triggered. The contact configuration includes 2 normally closed contacts and 1 normally open contact, enabling flexible integration into existing control and safety circuits. The output contacts are mechanically interlocked, meaning they are mechanically linked to prevent malfunction due to electrical or mechanical interference. This is a key component of the safety function.
Technology explained simply
The BH5932 operates with a PNP input, designed for connection to inductive proximity switches such as Dold models NA 5001, NA 5002, NA 5005 or NA 5010. These sensors detect the movement of a metallic object, e.g. a gear or hub, and transmit the signal to the monitor. The nominal voltage is AC/DC 24 V, enabling universal use in industrial control systems. The thermal current Ith max. is 4 A, indicating the maximum current load on the contacts.
Compatibility and accessories
The device is compatible with Dold proximity switches NA 5001.01.10, NA 5002.01.34, NA 5005.01.34 and NA 5010.01.10, with variants NA 5002.01.34 and NA 5005.01.34 only to be used with devices without initiator connection detection. The terminal assignment is defined in the datasheet for device type BH 5932, with brown, blue and black wires used for power and signal lines. The protection rating IP67 makes the device dust- and waterproof, allowing use outdoors or in damp environments.
Mounting and installation
The width is 45 mm, enabling mounting in standard 35 mm control panels. The terminal connections are designed for 2 x 1.5 mm² stranded wire with sleeve and plastic collar DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm² stranded wire with sleeve DIN 46 228-1/-2/-3. Mounting is done via screw terminals, ensuring a secure and durable connection.
Advantages in operation
The device meets safety requirements up to Category 3 and PL e according to EN ISO 13849-1 as well as SIL 3 according to IEC/EN 62061, guaranteeing high safety performance. The certifications UL-listed C/US, TÜV and CCC confirm compliance with international safety and quality standards. The mechanically interlocked contacts and fixed setpoint ensure reliable operation without adjustment. The integrated feedback circuit function X1–X2 enables monitoring of external contacts, increasing system integrity.
Certifications and safety standards
The BH5932 is classified as Category 3 and PL e according to EN ISO 13849-1, confirming its safety function in machine control systems. The SIL classification 3 according to IEC/EN 62061 demonstrates suitability for safety-critical applications in process and plant control systems. The certifications UL-listed C/US, TÜV and CCC underline the international usability of the device.
Safety functions
The mechanically interlocked contacts prevent unauthorized disconnection of the switching function, which is essential for safety-critical applications. The feedback circuit function X1–X2 enables monitoring of external contacts to ensure the integrity of the safety chain. The combination of fixed setpoint and PNP input ensures simple and reliable integration into existing systems.
Application safety
The device is designed for use in safety-relevant plants where malfunction could lead to damage or hazards. The certifications and safety classifications guarantee that the device meets the requirements of the Machinery Directive and Functional Safety. Use with suitable initiators such as Dold proximity switches NA 5001 to NA 5010 ensures safe signal transmission.