Dold 0056924, EAN: 4030641569242

Dold 0056924 emergency stop module BH5928.92/61 DC24V 3-30S

Industrial Material > Control devices / Pilot devices > Cam switch / power switch

Dold 0056924 emergency stop module BH5928.92/61 DC24V 3-30S

Lieske Part No. 286036
Mfg Part No 0056924
EAN-Code 4030641569242
Manufacturer Dold
Here only 507,41 EUR
603,82 EUR incl. VAT

Further information for Dold 0056924 emergency stop module BH5928.92/61 DC24V 3-30S

Technical data
1- / 2-channel1, 2
ApprovalsUL
Cat. / PL acc. to EN ISO 13849-14/e
ConnectionPluggable screw terminals
Output contacts max.3 NO contacts, 3 NO contacts delayed
SIL CL acc. to IEC/EN 620613
SIL acc. to IEC/EN 620613
Thermal current Ith max.5 A
Width45 mm
TypeBH 5928
Cross fault detectionYes
Suited as safety gate monitorYes
Variant
Contact equipping2 NO contacts, 1 NC contact instantaneous, 3 NO contacts off delay
Nominal voltageDC 24 V
Time range3 - 30 s
Approvals and MarkingsUL-listed C/US, TÜV, CCC
VariantWith adjustable time delay
The Dold BH5928.92/61 DC24V 3-30S is an emergency stop module with integrated time delay, designed for use in safety-critical applications in industrial automation. The device serves the protection function for personnel and machinery, particularly in emergency stop circuits where a stop category 1 must be implemented. It is also suitable for monitoring sliding safety grilles and can be used as a safety door monitor. The module width is 45 mm, making it suitable for standard control panels.

Applications
This module is used in industrial plants where safe shutdown is required in hazardous situations. It is particularly suitable for machines equipped with moving parts or safety grilles whose status must be monitored. The function as a safety door monitor enables monitoring whether a safety door is open, and triggers an emergency stop function in case of injury risk. The time delay of 3 to 30 seconds allows for controlled shutdown without immediately stopping the machine, which may be necessary in certain processes.

Functions and equipment in detail
The device features a contact configuration with 2 NO contacts, 1 NC contact immediately, and 3 NO contacts with delayed reset. The delayed reset contacts enable a time-delayed reset after triggering, which is necessary in certain applications to avoid false alarms or to ensure a controlled shutdown process. The connection technology is via removable screw terminals, enabling flexible and secure wiring. The conductor cross-sections are up to 2 x 2.5 mm² wire with sleeve DIN 46 228-1/-2/-3/-4. The status indication for the delayed reset time circuit, as well as LED indicators for power supply, channel 1/2, and time delay, support diagnosis and maintenance.

Technology explained clearly
The time delay is implemented via an adjustable time range of 3 to 30 seconds, thereby delaying the reset of contacts. The cross-connection detection at the single-button (terminals S33–S34) detects whether a short circuit exists in the control circuit, increasing safety. The activation occurs either via the single-button at S33–S34 or via an automatic activation function, which is enabled by a bridge at S13–S14. The safety functions are certified according to standards EN ISO 13849-1 (Performance Level PL e, Category 4) and IEC/EN 62061 (SIL CL 3), ensuring reliability in safety-critical applications. The thermal current Ith max. is 5 A, defining the contact load capacity.

Compatibility and accessories
The module is designed for 1- or 2-channel wiring, allowing flexible integration into various safety architectures. It is certified with UL-listed C/US, TÜV, CCC, confirming compliance with international safety standards. The approvals also include requirements according to IEC/EN 61508 and IEC/EN 61511 for SIL 3, emphasizing suitability for high-safety applications. No special accessories are required, as all functions are fully integrated into the device.

Mounting and installation
Mounting is done in standard control panels with a module width of 45 mm. The removable terminal blocks facilitate installation and maintenance. The connection terminals are clearly labeled, and the wiring diagrams in the datasheet support correct wiring. The single-button can be connected directly, or an automatic activation function is enabled via the bridge at S13–S14. The LED indicators allow for quick visual inspection of the operating status.

Advantages in operation
The combination of emergency stop function, time delay, and cross-connection detection provides high safety and reliability. The LED indicators support maintenance and fault diagnosis. The approvals according to EN ISO 13849-1 and IEC/EN 62061 guarantee suitability for safety-critical applications. The flexible wiring in 1- or 2-channel technology allows adaptation to various safety concepts. The removable terminals simplify installation and maintenance without requiring additional tools.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/286036