Dold 0056795, EAN: 4030641567958

Dold 0056795 MK9151N.12/002 2-450K AC24V 0.2-20S level relay

Dold 0056795 MK9151N.12/002 2-450K AC24V 0.2-20S level relay

Lieske Part No. 1001941
Mfg Part No 0056795
EAN-Code 4030641567958
Manufacturer Dold
Here only 177,05 EUR
210,69 EUR incl. VAT

Further information for Dold 0056795 MK9151N.12/002 2-450K AC24V 0.2-20S level relay

Technical data
ClassificationFüllstandsüberwachung
Enclosure designDistribution board
Measuring range max.450 kΩ
Output contacts2 x 1 C/O contacts
Width22,5 mm
TypeMK 9151N
Operate delayYes
Variant
Auxiliary voltageAC 24 V
Contact equipping2 x 1 changeover contact
Response and release delay0,2 - 20 s
Response value2 - 450 kOhm
Terminal typescrew terminals fixed
Approvals and MarkingsUKCA, CCC
VariantTime delay on Max level
The MK9151N.12/002 level relay from Dold is a device for monitoring the fill level of conductive liquids and powders, designed for use in industrial plants. It enables monitoring and control of maximum and minimum fill levels, for example to prevent overfilling or dry running. The device is part of the VARIMETER series and is installed in enclosures with mounting plate and cable duct. The width is 22.5 mm, the depth is 98 mm, with the connection terminals located at the top, which facilitates integration into existing control systems.

Applications
This relay is used for monitoring and controlling the fill level of conductive liquids and powders. It can be used to monitor mixing ratios of conductive liquids, for example in process plants. In addition, it is suitable for general resistance monitoring tasks, such as detecting a limit temperature using a PTC resistor. The application also includes the function as a contact protection relay with delay, where the time delay is only activated when the liquid level is exceeded.

Functions and equipment in detail
The device features three electrode connections (MIN, MAX, COM), which can be used for 1-point and 2-point level control. The setpoint is adjustable via a rotary switch in the range of 2 to 450 kΩ. The response and reset delay are separately adjustable for MIN and MAX levels and range from 0.2 to 20 seconds. Programming is done via jumpers on terminals X1-COM and X2-COM, allowing selection between separate and common control of the output relays, as well as between operating current and rest current principles. The operating current principle means that the output relay is activated in the event of a fault, while the rest current principle does not activate the relay in the event of a fault.

Technology explained simply
Measurement is performed via the electrical conductivity of the liquid between the electrodes. The reference electrode (COM) is typically mounted at the lowest point of the container and must always be connected to terminal COM. In conductive containers, the container itself can serve as the reference electrode. The counter electrodes for MIN and MAX are connected to the corresponding inputs. The output relays are each equipped with a changeover contact, enabling two independent switching functions. The LEDs for operational readiness (green) and for the MIN (yellow) and MAX (yellow) contact positions allow visual monitoring of the operating status.

Compatibility and accessories
The relay is designed for auxiliary voltages of AC 24 V, although the manufacturer also lists AC 24 to 400 V and DC 24 V as possible voltages. The terminal type is fixed screw terminals. Any commercially available electrodes can be used. Control is performed via terminals X1-COM and X2-COM, where the jumper configuration determines the operating mode. The devices are classified according to IEC/EN 60255-1 and carry the UKCA and CCC certifications.

Mounting and installation
Installation is carried out in enclosures with mounting plate and cable duct. The top-mounted connection terminals facilitate wiring. The depth of 98 mm and width of 22.5 mm are designed for standard control panels. The connection terminals are designed for fixed screw connections, ensuring a secure and durable connection.

Advantages in operation
The separate adjustability of setpoint and delay time for MIN and MAX levels allows precise adaptation to specific requirements. Programmability for different operating modes (separate or common control, operating current or rest current principle) offers flexibility in application. Visual indication via LEDs simplifies diagnosis and maintenance. The use of fixed screw terminals ensures a reliable electrical connection. The device is designed for use in industrial environments and complies with the standard IEC/EN 60255-1 as well as the UKCA and CCC certifications.

Compatibility
The device is designed for use with commercially available electrodes. Control is performed via terminals X1-COM and X2-COM, enabling various operating modes. The UKCA and CCC certifications as well as the IEC/EN 60255-1 standard ensure suitability for relevant applications.

Functions
The functions include level monitoring, 1-point and 2-point level control, adjustable setpoint and delay time, and visual indication via LEDs. Programmability for operating current and rest current principles extends the range of applications.

Application
The relay is used in industrial plants where precise monitoring of liquid levels is required, for example in filling systems, tanks or process plants. Installation in enclosures with mounting plate and cable duct is standard.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1001941
qrcode für Dold 0056795 MK9151N.12/002 2-450K AC24V 0.2-20S level relay